A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Commercial Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Molecular Assays: Superior Analytical Sensitivity of cobas SARS-CoV-2 Relative to NxTAG CoV Extended Panel and ID NOW COVID-19 Test. | LitMetric

Context.—: We implemented multiple nucleic acid amplification test platforms because of the limited availability of test kits for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) during the early stages of the pandemic. Interpretation of results generated by different platforms and prioritization for testing algorithms required cross-comparison.

Objective.—: To compare the analytical sensitivity of 3 commercial SARS-CoV-2 molecular assays, selected samples were studied in parallel with Cobas SARS-CoV-2 test, NxTAG CoV Extended Panel, and ID NOW COVID-19 assays.

Design.—: A total of 8043 SARS-CoV-2 tests performed from March 22 to April 19, 2020, were included in this study. For all 1794 positive specimens detected by the cobas SARS-CoV-2 assay, the cycle threshold (Ct) values were manually tracked and plotted to demonstrate the distribution of sample viral levels. Additionally, 50 and 63 low-positive specimens (Ct values >32) as well as 50 and 61 consecutive positive specimens by the cobas assay were tested with NxTAG and ID NOW, respectively, to estimate their relative sensitivities.

Results.—: The Ct values of cobas SARS-CoV-2-positive samples were evenly distributed throughout ranges of 13.32 to 39.50 (mean, 25.06) and 13.60 to 42.49 (mean, 26.45) for ORF1 and E gene targets, respectively. NxTAG reliably detected only specimens with E gene Ct values lower than 33, and is estimated to detect 89.4% of positive specimens detected by cobas assay. ID NOW had performance variation independent of Ct value and is estimated to detect 83.5% of cobas positives.

Conclusions.—: Clinical specimens exhibit a wide range of viral burden, with a significant portion at low levels. Analytical sensitivity of testing platforms is critical for reliable detection of SARS-CoV-2 and uniform care to patients.

Download full-text PDF

Source
http://dx.doi.org/10.5858/arpa.2020-0283-SADOI Listing

Publication Analysis

Top Keywords

analytical sensitivity
12
cobas sars-cov-2
12
positive specimens
12
severe acute
8
acute respiratory
8
respiratory syndrome
8
syndrome coronavirus
8
sars-cov-2
8
coronavirus sars-cov-2
8
sars-cov-2 molecular
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!