A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of Guided Implant Surgery in 25 Edentulous Arches: A Laboratory Observational Study. | LitMetric

Purpose: To assess the accuracy of template-guided implant surgery for edentulous arches.

Materials And Methods: The stone master casts of 25 edentulous arches treated with either 4 or 6 implants with CBCT generated template-guided surgery were included in this observational cohort study. The stone casts generated from the surgical templates (group one) prior to implant placement were digitized into Standard Tesselation (STL) files with a reference scanner. For comparison, the stone master casts derived from intraoral complete-arch impressions after implant placement (group two) were also digitized. The resultant STL files were superimposed and best-fit-alignment algorithm was used to quantify the 3D deviations present between the two groups. Descriptive statistics were computed for all categorical variables. Due to the presence of nonindependent samples between maxillary and mandibular casts, a mixed-effects model was used.

Results: Deviations between the implant analogs of the stone casts representing digitally planned versus actually placed implants were found. The mean root-mean-square error (RMSE) between all 25 arches was found to be 0.2 mm (SD ± 0.15). The mean RMSE between presurgical and postsurgical maxillary stone casts were 0.19 ± 0.15 mm, while between mandibular stone casts were 0.21 ± 0.16 mm and were not significant (p = 0.67). The mean RMSE between presurgical and postsurgical stone casts arches with 4 versus 6 implants were found to be significant (p = 0.01).

Conclusions: According to the results of the study and based on the amount of 3D deviations between the digitally planned implant positions and the actually placed implants, template-guided surgery is a safe treatment modality for implant placement in edentulous arches.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13224DOI Listing

Publication Analysis

Top Keywords

stone casts
20
edentulous arches
12
implant placement
12
implant surgery
8
surgery edentulous
8
stone master
8
casts
8
master casts
8
template-guided surgery
8
stl files
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!