Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: For patients with combined tricuspid and pulmonary valve disease, operative intervention carries high mortality risk. Published reports of combined transcatheter tricuspid and pulmonary valve replacement have been limited to single cases.
Methods: A retrospective chart review was performed including all patients undergoing combined transcatheter tricuspid and pulmonary valve replacement at the Ahmanson/UCLA Adult Congenital Heart Disease Center.
Results: Combined transcatheter tricuspid and pulmonary valve replacement was undertaken in five adult patients (median age: 46 years; range: 24-64 years). Three had congenital heart disease and two had carcinoid syndrome. Four patients had previous surgical tricuspid valve replacement and one had a surgical incomplete annuloplasty ring. Four patients had previous surgical pulmonary valve replacement and one had a right ventricle-to-pulmonary artery homograft conduit. Two patients underwent Medtronic Melody valve implantation in both tricuspid and pulmonary positions and three underwent Edwards Sapien S3 implantation in both tricuspid and pulmonary positions. Valve implantation was successful in all. Follow-up ranged from 0.9 to 3.0 years. One patient underwent redo transcatheter tricuspid valve replacement 12 months after the first transcatheter intervention for progressive regurgitation of a Melody valve. This patient died 2.5 years after combined valve placement of complications from refractory heart failure. The remaining patients were alive and free of valve reintervention at follow-up.
Conclusions: Combined transcatheter tricuspid and pulmonary valve replacement can be performed successfully, with an acceptable complication rate. This strategy is a feasible option for appropriately selected patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/2150135120918777 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!