Biodegradable stents are promising treatments for many diseases, e.g., coronary artery disease, urethral diseases, tracheal diseases, and esophageal strictures. The mechanical properties of biodegradable stent materials play a key role in the safety and efficacy of treatment. In particular, insufficient creep resistance of the stent material could result in premature stent collapse or narrowing. Commercially available biodegradable self-expandable SX-ELLA stents made of polydioxanone monofilament were tested. A new, simple, and affordable method to measure the shear modulus of tiny viscoelastic wires is presented. The important mechanical parameters of the polydioxanone filament were obtained: the median Young's modulus was [Formula: see text] = 958 (922, 974) MPa and the shear modulus was [Formula: see text] = 357 (185, 387) MPa, resulting in a Poisson's ratio of ν = 0.34. The SX-ELLA stents exhibited significant force relaxation due to the stress relaxation of the polydioxanone monofilament, approximately 19% and 36% 10 min and 48 h after stent application, respectively. However, these results were expected, and the manufacturer and implanting clinician should be aware of the known behavior of these biodegradable materials. If possible, a biodegradable stent should be designed considering therapeutic force rather than initial force. Additionally, new and more advanced biodegradable shape-memory polymers should be considered for future study and use.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7343154 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0235842 | PLOS |
J Complement Integr Med
November 2024
Other Specialist Medical Staff Group, RSUP Persahabatan, Jakarta, Indonesia.
Background: Myofascial pain characterized by myofascial trigger point (MTrP) is a common cause of musculoskeletal pain and the main cause of neck and shoulder pain in the working population. Thread embedding acupuncture (TEA) is a new modality that can provide long-term stimulation to prolong the same therapeutic effect as conventional acupuncture. This study aimed to determine the effect of TEA therapy on pain score, neck disability index (NDI), and pressure pain threshold (PPT) for myofascial pain in the upper trapezius muscle.
View Article and Find Full Text PDFOrbit
September 2024
Ophthalmology, Texas Oculoplastic Consultants, Austin, Texas, USA.
World J Surg
July 2024
Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Background: For abdominal fascial closure, the choice of optimal suture material and appropriate suture technique are of paramount importance to prevent the incidence of incisional hernia. Although barbed sutures are widely used in various surgical fields, their safety and feasibility on abdominal fascial closure which requires the most tensile strength for security have not been established yet.
Methods: We conducted a prospective, single-arm, interventional clinical trial to present the postoperative outcomes of using barbed sutures in abdominal fascial closure between April 2021 and August 2021.
Fetal Diagn Ther
October 2024
Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, Texas, USA.
Introduction: Suture tensile properties have only been tested in extrauterine environments. Amniotic fluid (AF) is a complex milieu of enzymes and inflammatory factors. This study tested the mechanical properties of sutures with a variety of inherent properties, after exposure to AF from patients with conditions prompting fetal intervention.
View Article and Find Full Text PDFFront Bioeng Biotechnol
October 2023
Kunming Medical University, Kunming Yunnan, China.
Independent augmentation technology based on reinforcing devices has been reported to signifi-cantly reduce the elongation behavior of graft and improve knee stability after anterior cruciate ligament reconstruction (ACLR). Using biodegradable devices could reduce the risk of severe inflammatory reactions due to particle accumulation from foreign bodies. Given the limitations of the mechanical properties of biodegradable materials, partially biodegradable composite devices may offer a compromise strategy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!