Biodegradable stents are promising treatments for many diseases, e.g., coronary artery disease, urethral diseases, tracheal diseases, and esophageal strictures. The mechanical properties of biodegradable stent materials play a key role in the safety and efficacy of treatment. In particular, insufficient creep resistance of the stent material could result in premature stent collapse or narrowing. Commercially available biodegradable self-expandable SX-ELLA stents made of polydioxanone monofilament were tested. A new, simple, and affordable method to measure the shear modulus of tiny viscoelastic wires is presented. The important mechanical parameters of the polydioxanone filament were obtained: the median Young's modulus was [Formula: see text] = 958 (922, 974) MPa and the shear modulus was [Formula: see text] = 357 (185, 387) MPa, resulting in a Poisson's ratio of ν = 0.34. The SX-ELLA stents exhibited significant force relaxation due to the stress relaxation of the polydioxanone monofilament, approximately 19% and 36% 10 min and 48 h after stent application, respectively. However, these results were expected, and the manufacturer and implanting clinician should be aware of the known behavior of these biodegradable materials. If possible, a biodegradable stent should be designed considering therapeutic force rather than initial force. Additionally, new and more advanced biodegradable shape-memory polymers should be considered for future study and use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7343154PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0235842PLOS

Publication Analysis

Top Keywords

polydioxanone monofilament
12
mechanical properties
8
properties biodegradable
8
biodegradable self-expandable
8
force relaxation
8
biodegradable stent
8
sx-ella stents
8
shear modulus
8
modulus [formula
8
[formula text]
8

Similar Publications

Background: Myofascial pain characterized by myofascial trigger point (MTrP) is a common cause of musculoskeletal pain and the main cause of neck and shoulder pain in the working population. Thread embedding acupuncture (TEA) is a new modality that can provide long-term stimulation to prolong the same therapeutic effect as conventional acupuncture. This study aimed to determine the effect of TEA therapy on pain score, neck disability index (NDI), and pressure pain threshold (PPT) for myofascial pain in the upper trapezius muscle.

View Article and Find Full Text PDF

Foreign body suture granuloma in canthal surgery: association with suture type.

Orbit

September 2024

Ophthalmology, Texas Oculoplastic Consultants, Austin, Texas, USA.

Article Synopsis
  • The study investigates the occurrence of suture granulomas, a complication in canthal surgery, focusing on their incidence and risk factors.
  • A total of 758 surgeries were reviewed, revealing that 2.4% resulted in granulomas, mainly linked to specific suture materials, particularly uncoated polyester.
  • Results suggest that using absorbable or monofilament sutures can significantly reduce the risk of developing suture granulomas after surgery.
View Article and Find Full Text PDF

Background: For abdominal fascial closure, the choice of optimal suture material and appropriate suture technique are of paramount importance to prevent the incidence of incisional hernia. Although barbed sutures are widely used in various surgical fields, their safety and feasibility on abdominal fascial closure which requires the most tensile strength for security have not been established yet.

Methods: We conducted a prospective, single-arm, interventional clinical trial to present the postoperative outcomes of using barbed sutures in abdominal fascial closure between April 2021 and August 2021.

View Article and Find Full Text PDF

Introduction: Suture tensile properties have only been tested in extrauterine environments. Amniotic fluid (AF) is a complex milieu of enzymes and inflammatory factors. This study tested the mechanical properties of sutures with a variety of inherent properties, after exposure to AF from patients with conditions prompting fetal intervention.

View Article and Find Full Text PDF

Independent augmentation technology based on reinforcing devices has been reported to signifi-cantly reduce the elongation behavior of graft and improve knee stability after anterior cruciate ligament reconstruction (ACLR). Using biodegradable devices could reduce the risk of severe inflammatory reactions due to particle accumulation from foreign bodies. Given the limitations of the mechanical properties of biodegradable materials, partially biodegradable composite devices may offer a compromise strategy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!