Accurate measurement of coagulation factors is essential, especially for diagnosis of deficiency. Clinical laboratories use commercially available plasma calibrators, which should be traceable to the relevant plasma International Standard (IS). This study assessed the relationship between the plasma IS for factors IX (FIX) and VIII (FVIII) and some commonly used commercial calibrators. Calibrators from seven manufacturers were assayed for FIX and FVIII activity by one-stage clotting assay (OSCA) using different activated partial thromboplastin time (APTT) reagents and deficient plasmas, or chromogenic assay (CA). Results were calculated relative to the 4th IS Factors II,VII,IX,X, Plasma or the 6th IS Factor VIII/VWF, Plasma. Results for each calibrator were similar across the APTT reagents and deficient plasmas used. All calibrators showed a recovery of 90%-111% of the manufacturers' values, except calibrator C, which had recovery of around 85%. CA gave similar results, with good recovery for all but calibrator C. Similar low recoveries for OSCA and CA were found for a different lot of calibrator C and for a different calibrator product from manufacturer C. When all calibrators from manufacturer C were assayed by OSCA using the manufacturer's own deficient plasmas and APTT reagents, the mean recovery was still below 90%. Overall, there was good traceability of the international unit between the IS and commercial calibrator plasmas. Calibrators from one manufacturer consistently yielded lower than expected values for FIX and FVIII. This could lead to an over-estimation of the coagulation factor content in patient samples and demonstrates the importance of careful choice of calibrator.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7754292 | PMC |
http://dx.doi.org/10.1111/ijlh.13277 | DOI Listing |
Am J Case Rep
January 2025
Department of Clinical Diagnostic Laboratories, Hospital Al-Sultan Abdullah, Puncak Alam, Selangor, Malaysia.
BACKGROUND Lupus anticoagulants (LA) can interfere with routine coagulation tests such as the activated partial thromboplastin time (aPTT) and prothrombin time (PT). The international normalized ratio (INR) is derived from PT and is used to monitor warfarin therapy. A positive LA result is one of the laboratory criteria of the 2023 ACR/EULAR antiphospholipid syndrome (APS) classification criteria.
View Article and Find Full Text PDFBlood
January 2025
Cleveland Clinic, Cleveland, Ohio, United States.
Antibodies to β2-glycoprotein I (β2GPI) cause thrombosis in antiphospholipid syndrome, however the role of β2GPI in coagulation in vivo is not understood. To address this issue, we developed β2GPI-deficient mice (Apoh-/-) by deleting exon 2 and 3 of Apoh using CRISPR/Cas9 and compared the development of thrombosis in wild-type (WT) and Apoh-/- mice using rose bengal and FeCl3-induced carotid thrombosis, laser-induced cremaster arteriolar injury, and inferior vena cava (IVC) stasis models. We also compared tail bleeding times and activation of platelets from WT and Apoh-/- mice in the absence and presence of β2GPI.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
Laboratory of Molecular Medicine, Ordos Central Hospital, Inner Mongolia Autonomous Region, Ordos 017000, China; Ordos Clinical Medical College, Inner Mongolia Medical University, Ordos 017000, China; Baotou Medical College, Inner Mongolia University of Science and Technology, Baotou 014000, China. Electronic address:
Salivary proteins of ticks can inhibit host hemostatic and inflammatory responses during the blood-sucking process of the parasites. A cDNA sequence, Hq021, was identified from a cDNA library of Haemaphysalis qinghaiensis. Hq021 encodes a mature protein containing 182 amino acids with a molecular mass of 20.
View Article and Find Full Text PDFVox Sang
January 2025
Division of Neonatology, Willem-Alexander Children's Hospital, Leiden University Medical Center, Leiden, the Netherlands.
Background And Objectives: Routine coagulation screens at birth are still standard in some European neonatal intensive care units (NICUs), although interpretation of these results is complex in preterm infants. It is unclear to what extent local coagulation assay results agree with published reference ranges when using different analysers and reagents. We aimed to assess coagulation assay results on day 1 of life in very preterm infants admitted to the NICU.
View Article and Find Full Text PDFTH Open
July 2024
Department of Laboratory Hematology, Pontchaillou University Hospital of Rennes, France.
Nowadays, unfractionated heparin (UFH) use is limited to selected patient groups at high risk of both bleeding and thrombosis (patients in cardiac surgery, in intensive care unit, and patients with severe renal impairment), rendering its management extremely challenging, with many unresolved questions despite decades of use. In this narrative review, we revisit the fundamental concepts of therapeutic anticoagulation with UFH and address five key points, summarizing controversies underlying the use of UFH and discussing the few recent advances in the field: (1) laboratory tests for UFH monitoring have significant limitations; (2) therapeutic ranges are not well grounded; (3) the actual influence of antithrombin levels on UFH's anticoagulant activity is not well established; (4) the concept of UFH resistance lacks supporting data; (5) scarce data are available on UFH use beyond acute venous thromboembolism. We therefore identified key issues to be appropriately addressed in future clinical research: (1) while anti-Xa assays are often considered as the preferred option, we call for a vigorous action to improve understanding of the differences between types of anti-Xa assays and to solve the issue of the usefulness of added dextran; (2) therapeutic ranges for UFH, which were defined decades ago using reagents no longer available, have not been properly validated and need to be confirmed or reestablished; (3) UFH dose adjustment nomograms require full validation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!