Better accurate stethoscope measurements have been needed to diagnose heart problems earlier, monitor patients, and provide initial clinical data for physicians. This study aims to evaluate an electronic stethoscope for automatic identification of heart rate by monitoring Beats Per Minute (BPM) in real-time. In this work, a new design with a low cost electronic stethoscope is designed and implemented as a simple circuit for a replacement with conventional stethoscopes. This presented a low cost stethoscopes consisting of a preamplifier, low-pass filter, high-pass filter, microcontroller and Bluetooth. This simulation and experimental study was carried out for electronic circuit design testing. The condenser microphone transmited the signal into the signal conditioning circuit, and amplified it from 10 to 30 times. The low- and high- pass filter circuit was with cutoffs of 180 Hz and 50 Hz, respectively. The result shows that the fourth-order Butterworth filter was the best filter, with a gain of 0.707 Volt, -3.01 dB, and 0.782 Volt, -2.137 dB, respectively. The real-time measurements using the system are not significantly different from the manual measurements, with around 2-5%, with a delay of 1.7 to 2 seconds. The results indicated that an electronic stethoscope system could provide suitable information for BPM value and could display heart sound signals.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7321389 | PMC |
http://dx.doi.org/10.31661/jbpe.v0i0.1183 | DOI Listing |
Cureus
December 2024
Physiology, American University of Antigua, St. John's, ATG.
Wearable technology, including devices like Apple and Samsung watches, Fitbits, and smart rings, has become widely popular. However, while these consumer electronics are readily available, they do not yet meet the accuracy and safety standards required for medical devices by the U.S.
View Article and Find Full Text PDFActas Urol Esp (Engl Ed)
November 2024
Servicio Urología, Hospital del Trabajador, Santiago, Chile.
Occup Med (Lond)
November 2024
School of Medicine and Surgery, University of Milano-Bicocca, Monza 20900, Italy.
This article explores two case reports of healthcare students with hearing impairments in an Italian university and the accommodations provided during their clinical training. The first student, with bilateral sensorineural hearing loss, used the Contec Visual Electronic Stethoscope CMS-VE, which amplifies the sound up to 32 times and supports earphones while wearing hearing aids. The second student, with profound bilateral sensorineural hearing loss and cochlear implants, utilized the Littmann CORE Digital Stethoscope, which amplifies the sound up to 40 times and transmits it via Bluetooth.
View Article and Find Full Text PDFSensors (Basel)
October 2024
Division of Respirology, Department of Medicine, McMaster University, Hamilton, ON L8S 4L7, Canada.
This paper presents a comprehensive review of cardiorespiratory auscultation sensing devices (i.e., stethoscopes), which is useful for understanding the theoretical aspects and practical design notes.
View Article and Find Full Text PDFVet J
December 2024
Department of Animal Biosciences, Swedish University of Agricultural Sciences P.O. Box 7028, Uppsala 750 07, Sweden.
Brachycephalic Obstructive Airway Syndrome (BOAS) is a potentially life-threatening condition that can be challenging to diagnose and grade objectively. The aim of this study was to investigate the use of respiratory signal analysis to assess severity of BOAS in dogs. Hundred and seventeen client-owned dogs of brachycephalic and non-brachycephalic breeds were enrolled.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!