Radionecrosis (RN) is the most important side effect after stereotactic radiotherapy (SRT) for brain metastases, with a reported incidence ranging from 3% to 24%. To date, there are no unanimously accepted criteria for iconographic diagnosis of RN, as well as no definitive dose-constraints correlated with the onset of this late effect. We reviewed the current literature and gave an overview report on imaging options for the diagnosis of RN and on dosimetric parameters correlated with the onset of RN. We performed a PubMed literature search according to the preferred reporting items and meta-analysis (PRISMA) guidelines, and identified articles published within the last ten years, up to 31 December 2019. When analyzing data on diagnostic tools, perfusion magnetic resonance imaging (MRI) seems to be very useful allowing evaluation of the blood flow in the lesion using the relative cerebral blood volume (rCBV) and blood vessel integrity using relative peak weight (rPH). It is necessary to combine morphological with functional imaging in order to match information about lesion morphology, metabolism and blood-flow. Eventually, serial imaging follow-up is needed. Regarding dosimetric parameters, in radiosurgery (SRS) V12 < 8 cm and V10 < 10.5 cm of normal brain are the most reliable prognostic factors, whereas in hypo-fractionated stereotactic radiotherapy (HSRT) V18 and V21 are considered the main predictive independent risk factors of RN.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7565332 | PMC |
http://dx.doi.org/10.3390/jpm10030059 | DOI Listing |
Sci Rep
January 2025
Radiation Safety and Quality Assurance division, National Cancer Center Hospital East, Chiba, 277-8577, Japan.
The impact of three-dimensional (3D) dose delivery accuracy of C-arm linacs on the planning target volume (PTV) margin was evaluated for non-coplanar intracranial stereotactic radiosurgery (SRS). A multi-institutional 3D starshot test using beams from seven directions was conducted at 22 clinics using Varian and Elekta linacs with X-ray CT-based polymer gel dosimeters. Variability in dose delivery accuracy was observed, with the distance between the imaging isocenter and each beam exceeding 1 mm at one institution for Varian and nine institutions for Elekta.
View Article and Find Full Text PDFEur J Cancer
January 2025
National Center for Cancer Immune Therapy, Department of Oncology, Copenhagen University Hospital, Herlev, Denmark. Electronic address:
Introduction: Advances in modern therapies have improved outcomes for patients with melanoma brain metastases (MBM), though prognosis remains poor. The optimal treatment strategy for patients who do not meet clinical trial inclusion criteria is unclear.
Methods: This study included all patients with MBM diagnosed in Denmark between 2015 and 2022, identified through the Danish Metastatic Melanoma Database (DAMMED) and local surgical and radiotherapy records.
Seizure
January 2025
Department of Clinical Neurological Sciences, Western University, London, ON. Canada; Department of Paediatrics, Western University, London, ON. Canada. Electronic address:
Objective: To conduct a systematic review on radiofrequency thermocoagulation (RF-TC) in pediatric epilepsy surgery. In addition, due to the low number of dedicated pediatric series, to conduct a pooled analysis of cases published in the literature.
Methods: We conducted a literature search using PUBMED and EMBASE which produced 432 results.
Phys Med Biol
January 2025
Radiotherapy and Radiosurgery department, Iatropolis Clinic, 54 Ethnikis Antistaseos ave., Athens, Attica, 15231, GREECE.
Using the concept of biologically effective dose (BED), the effect of sublethal DNA damage repair (SLR) on the bio-efficacy of prolonged radiotherapy treatments can be quantified (BED). Such treatments, lasting more than 20 min, are typically encountered in stereotactic radiosurgery (SRS) applications using the CyberKnife (CK) and Gamma knife systems. Evaluating the plan data from 45 Vestibular Schwannoma (VS) cases treated with single fraction CK-SRS, this work demonstrates a statistically significant correlation between the marginal BEDSLR delivered to the target (m-BEDSLR) and the ratio of the mean collimator size weighted by the fraction of total beams delivered with each collimator ((_w^m)Cs), to the tumor volume (Tv).
View Article and Find Full Text PDFMed Phys
January 2025
Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation Radiobiologie et Cancer, Orsay, France.
Background: Breast cancer is the leading cause of female cancer mortality worldwide, accounting for 1 in 6 cancer deaths. Surgery, radiation, and systemic therapy are the three pillars of breast cancer treatment, with several strategies developed to combine them. The association of preoperative radiotherapy with immunotherapy may improve breast cancer tumor control by exploiting the tumor radio-induced immune priming.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!