A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of Circulating Levels of Uremic Toxins in Hemodialysis Patients Treated with Medium Cut-Off Membranes and High-Flux Membranes: Theranova in Sisli Hamidiye Etfal (THE SHE) Randomized Control Study. | LitMetric

Introduction: Removal of uremic toxins is a main objective of hemodialysis; however, whether high-flux and medium cut-off (MCO) membranes differ as regards removal of middle and large uremic toxins is not clear.

Objective: To compare medium cut-off and high-flux dialyzers as regards their intra- and interdialysis effect on circulating levels of middle and large uremic toxins and serum albumin.

Methods: Fifty-two patients were randomized to have hemodialysis with either 3 months of high-flux dialyzer followed by 3 months of MCO or vice versa. Blood samples were taken before and after dialysis at the first and last sessions of each dialyzer for analyses of middle and large uremic toxins including inflammatory mediators and vascular endothelial growth factor (VEGF), and serum albumin.

Results: Reduction rates were higher, and postdialysis levels of β-2 microglobulin, free kappa and lambda light chains, and myoglobulin were lower at the first and last sessions with MCO dialyzers compared to high-flux dialyzers (p < 0.05 for all). Last session predialysis levels of β-2 microglobulin, free kappa light chain, and free lambda light chain were lower than first session predialysis levels in MCO dialyzers as compared to high-flux dialyzers (p < 0.05 for all). Last session levels of interleukin-6, interleukin-10, interleukin-17, and interferon-gamma did not differ between dialyzers (p > 0.05 for all). VEGF level was lower in the MCO group compared to the high-flux group (p = 0.043). Last session level of serum albumin with MCO dialyzers was lower than that with high-flux dialyzers (3.62 [3.45-3.88] vs. 3.78 [3.58-4.02] g/L) (p = 0.04) and 6.7% lower (p < 0.001) than at the first session of MCO dialyzers.

Conclusion: The decline in circulating levels of several middle and large uremic toxins including VEGF following hemodialysis was more pronounced when using MCO membranes as compared to high-flux membranes while their effect on inflammatory molecules was similar.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000508061DOI Listing

Publication Analysis

Top Keywords

uremic toxins
24
middle large
16
large uremic
16
high-flux dialyzers
16
compared high-flux
16
circulating levels
12
medium cut-off
12
mco dialyzers
12
dialyzers 005
12
high-flux
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!