Background: The efficacy of oral appliance (OA) varies greatly in patients with obstructive sleep apnoea (OSA).

Objective(s): The purpose of this cross-sectional study was to investigate the success rate of OA for OSA patients.

Methods: This study was based on a cross-sectional multicentre survey of OA therapy for the management of OSA called the JAMS (Japanese Cross-sectional Multicenter Survey) Study performed at 10 medical institutions. A total of 442 patients fulfilled the selection criteria, which patients had worn OA, and undergone overnight polysomnography to assess both the pre-treatment baseline and follow-up for OA. Age, sex, BMI and apnoea-hypopnea index (AHI) at the time of diagnosis and follow-up for OA were extracted.

Results: After OA treatment, the mean AHI decreased from 22.6 ± 13.8 to 10.0 ± 10.2/h, and the mean rate of decrease in the AHI was 52.5 ± 38.4%. Regarding the success rate to OA therapy, criterion 1 (AHI < 5/h), criterion 2 (AHI < 10/h), criterion 3 (AHI < 15/h) and criterion 4 (AHI reduction rate ≥ 50%) accounted for 33.5, 66.3, 80.5 and 63.3%, respectively. The success rate of OA treatment decreased according to the increase in OSA severity, obesity level (higher BMI) and older age.

Conclusions: This study revealed the treatment success rate of OA on multiple criteria according to OSA severity, BMI and age. It may support for the clinician to make a decision on the OSA management.

Download full-text PDF

Source
http://dx.doi.org/10.1111/joor.13046DOI Listing

Publication Analysis

Top Keywords

success rate
12
obstructive sleep
8
sleep apnoea
8
rate oral
4
oral appliances
4
appliances based
4
based multiple
4
multiple criteria
4
criteria obstructive
4
apnoea severity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!