Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The non-radioactive method that uses the magnetic tracer (SPIO/Sienna) has shown to be a feasible technique for the SLN detection in breast cancer patients. The aim of this study is to assess the efficacy of different doses of a new magnetic tracer Sienna XP (Magtrace) compared to Tc-99 m and to evaluate its non-inferiority.
Methods: Patients diagnosed with early-stage breast cancer cT1-3 N0, from October 2016 to August 2018 were eligible and consecutively randomized to three different doses of new SPIO used: group 1 (1 mL), group 2 (1.5 mL) and group 3 (2 mL).
Results: A total of 135 patients were included in the study, 45 in each group. Detection of SLNs with the three doses of Sienna XP (1 mL, 1.5 mL and 2 mL) showed non-inferior rates compared to the conventional technique with radiotracer (p = 0.654). Concordance by patients with SLN positive was 100% for all groups. 83 (70.3%) patients reported skin staining at one month postoperatively, significantly lower in group 1 (p = 0.042). At 6 months follow up, group 1 remains with significantly lower skin discoloration (p = 0,01). In multivariate analysis, dose of 2 mL showed statistically significant for the skin staining. The majority of patients (70%) felt that skin discoloration does not represent a problem.
Conclusion: The use of the Sienna XP magnetic tracer at 1 mL is not inferior to higher doses of magnetic tracer neither is inferior to radiotracer. 1 mL of magnetic tracer resulted in significantly less skin discoloration compared to higher doses.