In the absence of a ⩒o2-work-rate plateau, debate continues regarding the best way to verify that the peak ⩒o2 achieved during incremental exercise (⩒o2peak) is the "true ⩒o2max." Oft-used "secondary criteria" have been questioned in conjunction with the contention that a severe-intensity constant-work-rate "verification bout" should be considered the "gold standard." The purpose of this study was to compare the ⩒o2peak during ramp incremental cycling (RAMP-INC) by a heterogeneous (with respect to body composition and sex) cohort of sedentary individuals with the ⩒o2peak during severe-intensity constant-work-rate cycling (CWR) performed after RAMP-INC at the highest work rate achieved. A secondary purpose was to determine the degree to which traditional and newly-proposed age-dependent secondary criteria (RER, HR) identified RAMP-INC which CWR confirmed were characterized by a submaximal ⩒o2peak. Thirty-five healthy male (n = 19: 33.4 ± 6.3 yrs) and female (26.8 ± 3.6 yrs) sedentary participants performed RAMP-INC followed by CWR. The ⩒o2peak values from the two tests were correlated (r = 0.96; p < 0.01; mean CV = 24%); however, ⩒o2peak for CWR was significantly greater (29.6 ± 7.2 v. 28.6 ± 6.8 mL∙min-1∙kg-1; p < 0.01) with a mean bias of 0.98 mL∙min-1∙kg-1 (z = -2.9, p < 0.01). Both traditional and newly-proposed criterion values for RER were achieved during RAMP-INC by 33 of 35 participants (including 21 of 23 who registered a higher ⩒o2peak on CWR). The traditional HR criterion value was achieved on only seven tests (three of which were confirmed to be characterized by a submaximal ⩒o2peak) while use of less stringent newly-proposed criteria resulted in acceptance of an additional seven tests of which five were confirmed to be submaximal. Severe-intensity CWR to limit of tolerance indicates that RAMP-INC underestimates ⩒o2max in sedentary individuals and both traditional and newly-proposed secondary criteria are ineffective for identifying such tests.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7337348PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0235567PLOS

Publication Analysis

Top Keywords

severe-intensity constant-work-rate
12
sedentary individuals
12
traditional newly-proposed
12
constant-work-rate cycling
8
ramp incremental
8
incremental cycling
8
underestimates ⩒o2max
8
cohort sedentary
8
⩒o2peak
8
performed ramp-inc
8

Similar Publications

Introduction: This study aimed to analyze the effect of caffeine (CAF) intake on pulmonary oxygen uptake (V˙O2) kinetics, muscle fatigue, and physiological and perceptual parameters during severe-intensity cycling exercise.

Methods: Twelve physically active men (age: 26 ± 5 years; V˙O2peak: 46.7 ± 7.

View Article and Find Full Text PDF

Purpose: This study examined the impact of a 5-wk sprint interval training (SIT) intervention on time to task failure (TTF) during severe-intensity constant work rate (CWR) exercise, as well as in glycolytic enzymatic content and activity, and glycogen content.

Methods: Fourteen active males were randomized into either a SIT group ( n = 8) composed of 15 SIT sessions over 5 wk, or a control group ( n = 6). At pretraining period, participants performed i) ramp incremental test to measure the cardiorespiratory function; ii) CWR cycling TTF at 150% of the power output (PO) at the respiratory compensation point (RCP-PO) with muscle biopsies at rest and immediately following task failure.

View Article and Find Full Text PDF

Cardiovascular responses of exercises performed within the extreme exercise domain.

Physiol Res

July 2023

Department of Coaching Education, Faculty of Sports Sciences, Adnan Menderes University, Aydin, Republic of Türkiye, Department of Coaching Education, Faculty of Sports Sciences, Ege University, Izmir, Republic of Türkiye.

Stroke volume (SV), heart rate (HR) and arterio-venous O2 difference (a-vO2diff) responses to heavy and severe-intensity exercise have been well documented; however, there is a lack of information on the SV, HR and a v-O2diff responses of work rates within extreme exercise domain. The aim of this study was, therefore, to focus on central and peripheral components of VO2 responses to exercises performed within the heavy, severe and extreme exercise domain. Eight well-trained male cyclists participated in this study.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates the reliability and validity of a three-minute all-out test (3MT) to estimate an athlete's maximum metabolic steady state (MMSS) in a remote setting.
  • Fifty-three trained cyclists and triathletes participated in trials to assess the consistency of 3MT results, while a subgroup underwent additional tests to compare the 3MT findings to direct measurements of MMSS.
  • Results showed that while the 3MT was reliable in measuring end-test power output, it tended to overestimate MMSS, indicating it may not be suitable for endurance-trained athletes to evaluate their metabolic performance.
View Article and Find Full Text PDF

Shorter constant work rate cycling tests as proxies for longer tests in highly trained cyclists.

PLoS One

May 2022

Centre of Human Performance, School of Medical and Health Sciences, Edith Cowan University, Joondalup, Western Australia, Australia.

Severe-intensity constant work rate (CWR) cycling tests simulate the high-intensity competition environment and are useful for monitoring training progression and adaptation, yet impose significant physiological and psychological strain, require substantial recovery, and may disrupt athlete training or competition preparation. A brief, minimally fatiguing test providing comparable information is desirable. Purpose To determine whether physiological variables measured during, and functional decline in maximal power output immediately after, a 2-min CWR test can act as a proxy for 4-min test outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!