A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sample size and rejection limits for detecting reagent lot variability: analysis of the applicability of the Clinical and Laboratory Standards Institute (CLSI) EP26-A protocol to real-world clinical chemistry data. | LitMetric

Objectives: To maintain the consistency of laboratory test results, between-reagent lot variation should be verified before using new reagent lots in clinical laboratory. Although the Clinical and Laboratory Standards Institute (CLSI) document EP26-A deals with this issue, evaluation of reagent lot-to-lot difference is challenging in reality. We aim to investigate a practical way for determining between-reagent lot variation using real-world data in clinical chemistry.

Methods: The CLSI EP26-A protocol was applied to 83 chemistry tests in three clinical labs. Three criteria were used to define the critical difference (CD) of each test as follows: reference change value and total allowable error, which are based on biological variation, and acceptable limits by external quality assurance agencies. The sample size and rejection limits that could detect CD between-reagent lots were determined.

Results: For more than half of chemistry tests, reagent lot-to-lot differences could be evaluated using only one patient sample per decision level. In many cases, the rejection limit that could detect reagent lot-to-lot difference with ≥90% probability was 0.6 times CD. However, the sample size and rejection limits vary depending on how the CD is defined. In some cases, impractical sample size or rejection limits were obtained. In some cases, information on sample size and rejection limit that met intended statistical power was not found in EP26-A.

Conclusions: The CLSI EP26-A did not provide all necessary answers. Alternative practical approaches are suggested when CLSI EP26-A does not provide guidance.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2020-0454DOI Listing

Publication Analysis

Top Keywords

sample size
20
size rejection
20
rejection limits
16
clsi ep26-a
16
clinical laboratory
12
reagent lot-to-lot
12
laboratory standards
8
standards institute
8
institute clsi
8
ep26-a protocol
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!