New Findings: What is the central question of this study? Do individuals with a patent foramen ovale (PFO ) have a larger alveolar-to-arterial difference in ( ) than those without (PFO ) and/or an exaggerated increase in pulmonary artery systolic pressure (PASP) in response to hypoxia? What is the main finding and its importance? PFO had a greater while breathing air, 16% and 14% O , but not 12% or 10% O . PASP increased equally in hypoxia between PFO and PFO . These data suggest that PFO may not have an exaggerated acute increase in PASP in response to hypoxia.

Abstract: Patent foramen ovale (PFO) is present in 30-40% of the population and is a potential source of right-to-left shunt. Accordingly, those with a PFO (PFO ) may have a larger alveolar-to-arterial difference in ( ) than those without (PFO ) in normoxia and with mild hypoxia. Likewise, PFO is associated with high-altitude pulmonary oedema, a condition known to have an exaggerated pulmonary pressure response to hypoxia. Thus, PFO may also have exaggerated pulmonary pressure increases in response to hypoxia. Therefore, the purposes of the present study were to systematically determine whether or not: (1) the was greater in PFO than in PFO in normoxia and mild to severe hypoxia and (2) the increase in pulmonary artery systolic pressure (PASP) in response to hypoxia was greater in PFO than in PFO . We measured arterial blood gases and PASP via ultrasound in healthy PFO (n = 15) and PFO (n = 15) humans breathing air and 30 min after breathing four levels of hypoxia (16%, 14%, 12%, 10% O , randomized and balanced order) at rest. The was significantly greater in PFO compared to PFO while breathing air (2.1 ± 0.7 vs. 0.4 ± 0.3 Torr), 16% O (1.8 ± 1.2 vs. 0.7 ± 0.8 Torr) and 14% O (2.3 ± 1.2 vs. 0.7 ± 0.6 Torr), but not 12% or 10% O . We found no effect of PFO on PASP at any level of hypoxia. We conclude that PFO influences pulmonary gas exchange efficiency with mild hypoxia, but not the acute increase in PASP in response to hypoxia.

Download full-text PDF

Source
http://dx.doi.org/10.1113/EP088750DOI Listing

Publication Analysis

Top Keywords

pfo
22
pasp response
16
pfo pfo
16
response hypoxia
16
pulmonary artery
12
patent foramen
12
foramen ovale
12
breathing air
12
12% 10%
12
greater pfo
12

Similar Publications

Objective: This study aims to examine the changes in metabolic profiles in patients with patent foramen ovale (PFO) and migraine, as well as in patients with isolated migraine, before and after surgical intervention using metabolomics.

Methods: Patients were categorized into four groups: the simple migraine (SM) group, the PFO with migraine preoperative group (PRE), the PFO with migraine postoperative Day 3 group (POST_3d), and the PFO with migraine postoperative Day 30 group (POST_30d). Untargeted metabolomics using liquid chromatography-mass spectrometry (LC-MS) were employed to identify differential metabolites across these groups.

View Article and Find Full Text PDF

Transport mechanisms of the anthropogenic contaminant sulfamethoxazole in volcanic ash soils at equilibrium pH evaluated using the HYDRUS-1D model.

J Hazard Mater

January 2025

Facultad de Química y de Farmacia, Pontificia Universidad Católica de Chile, Vicuña Mackenna 4860, Santiago 7820436, Chile; Instituto para el Desarrollo Sustentable, Pontificia Universidad Católica de Chile, Vicuña Mackenna 4860, Santiago 7820436, Chile; Centro para el Desarrollo de la Nanociencia y Nanotecnología, CEDENNA, Santiago, Chile. Electronic address:

The volcanic soils in Chile, where a significant portion of agricultural activities take place, are impacted by the presence of veterinary drugs, including sulfamethoxazole (SMX). The study examines how different soil types influence the movement and retention of sulfamethoxazole (SMX) across four regions of Chile, focusing on conditions at a neutral pH of 7.0.

View Article and Find Full Text PDF

A thrombus straddling a patent foramen ovale (TSPFO) is a rare condition that presents significant health risks, including stroke or myocardial infarction, and can be life-threatening if not promptly addressed. We report the case of a 42-year-old female with morbid obesity who presented with sudden shortness of breath due to a bilateral pulmonary embolism. Imaging revealed a thrombus extending from the right atrium to the left atrium through the patent foramen ovale (PFO).

View Article and Find Full Text PDF

Background: About 30% of ischemic strokes do not have a clear cause, which is called cryptogenic stroke (CS). Increasing evidence suggests a potential link between CS and right-to-left shunt (RLS). RLS may lead to CS via paradoxical embolic mechanism.

View Article and Find Full Text PDF

We aimed to evaluate the incidence of residual shunt after patent foramen ovale (PFO) closure and analyze the anatomical features of PFO to determine the risk factors for significant residual shunt after PFO closure. Ninety-two patients who underwent PFO closure at our center between September 2021 and June 2022 were consecutively enrolled. Transthoracic saline contrast echocardiography was performed at 6 and 12 months postoperatively to evaluate the presence of a significant residual shunt.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!