Coronary angioscopy (CA) was performed in 30 patients (pts) during cardiac catheterization (Group 1) and in 11 pts during coronary bypass surgery (Group 2) using ultrathin fiberoptic angioscopes (phi 1.2-1.8 mm). For percutaneous CA (Group 1) the angioscope was introduced through a 9F guiding catheter from the femoral artery. The viewing field was cleared by flushing Ringer's solution and short-time occlusion of the coronary ostium by the guiding catheter. In Group 2 CA was performed retrogradely from the distal arteriotomy and through the bypass vein during flushing with cardioplegic solution. In Group 1 in 17/30 pts the coronary artery could be successfully examined by CA. In 13 pts the obstruction was eccentric and irregular shaped. In 2/5 pts, in whom CA was performed successfully pre and post balloon dilatation, CA after PTCA revealed an intimal rupture without clinical or angiographical signs of the intimal dissection. In Group 2 in 9/11 pts good visualization of stenoses could be achieved. At the obstruction site CA revealed thrombi in 3 pts and ulcer in 1 pts. In contrast to angiography, which estimates the lumen diameter of a segmental lesion, CA gives information about the luminal shape and the underlying substance of the obstruction (e.g. atheroma, thrombus, ulceration). The main problems in percutaneous CA are the insufficient intraluminal guidance, the insufficient depth of view of the angioscopes, and the limited examination time.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF01814888DOI Listing

Publication Analysis

Top Keywords

coronary angioscopy
8
cardiac catheterization
8
pts
8
pts coronary
8
guiding catheter
8
group
6
coronary
5
angioscopy cardiac
4
catheterization cardiac
4
cardiac surgery
4

Similar Publications

Background: Coronary stenting operations have become the main option for the treatment of coronary heart disease. Vessel recovery after stenting has emerged as a critical factor in reducing possible complications. In this study, we evaluated the feasibility, safety and efficacy of locally administered intraluminal gene therapy delivered using a specialized infusion balloon catheter.

View Article and Find Full Text PDF

In this paper, we present the design and fabrication of a novel chip-on-tip catheter, which uses a microcamera and optical fibres to capture in vivo images in a beating porcine heart thanks to a saline flush to clear the blood field. Here, we demonstrate the medical utility and mechanical robustness of this catheter platform system, which could be used for other optical diagnostic techniques, surgical guidance, and clinical navigation. We also discuss some of the challenges and system requirements associated with developing a miniature prototype for such a study and present assembly instructions.

View Article and Find Full Text PDF

This study aimed to explore the impact of cardiac rehabilitation (CR) on in vivo and ex vivo microcirculation, exercise capacity, and oxidative stress in patients with cardiovascular disease (CVD). The study included patients with acute coronary syndrome (ACS; n = 45; age, 69.0 ± 14.

View Article and Find Full Text PDF

Lipid-lowering therapy plays a central role in reducing cardiovascular events. Over the past few decades, clinical trials utilizing several imaging techniques have consistently shown that lipid-lowering therapy can reduce the coronary plaque burden and improve plaque composition. Although intravascular ultrasound has been the most extensively used modality to assess plaque burden, other invasive modalities, such as optical coherence tomography and near-infrared spectroscopy, provide relevant data on plaque vulnerability, and computed tomography angiography detects both plaque volume and characteristics non-invasively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!