A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

RADIATION DOSES TO THE EYE LENS AND FOREHEAD OF INTERVENTIONAL RADIOLOGISTS: HOW HIGH AND ON WHAT GROUNDS? | LitMetric

RADIATION DOSES TO THE EYE LENS AND FOREHEAD OF INTERVENTIONAL RADIOLOGISTS: HOW HIGH AND ON WHAT GROUNDS?

Radiat Prot Dosimetry

2nd Department of Radiology, Medical Physics Unit, National and Kapodistrian University of Athens, Attikon University Hospital, 12462, Athens, Greece.

Published: August 2020

The aim of the study was to measure and evaluate the radiation dose to the eye lens and forehead of interventional radiologists (IRs). The study included 96 procedures (lower-limb percutaneous transluminal angioplasties, embolisations/chemoembolisations and vertebroplasties) performed by 6 IRs. A set of seven thermoluminescence dosemeters was allocated to each physician. The highest dose per procedure was found for the left eye lens of the primary operator in vertebroplasties (1576 μSv). Left and right eye doses were linearly correlated to left and right forehead doses, respectively. A workload-based estimation of the annual dose to participating IRs revealed that the occupational dose limit for the eye lens can be easily exceeded. The left eye dose of ΙRs must be routinely monitored on a personalised basis. Τhe left eye dose measurement provides a reliable assessment of the ipsilateral forehead dose, along with valid estimations for the right eye and right forehead doses.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncaa097DOI Listing

Publication Analysis

Top Keywords

eye lens
16
left eye
16
eye
8
lens forehead
8
forehead interventional
8
interventional radiologists
8
forehead doses
8
eye dose
8
dose
7
forehead
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!