Ratiometric fluorescent l-arginine (Arg) and l-asparagine (Asn) biosensors were developed using an oxazine 170 perchlorate (O17) ethyl cellulose (EC) membrane and the enzymes entrapped into the matrix of EC and hydrogel polyurethane. The sensing principles were based on the hydrolysis reactions of urea and l-Arg under the catalysis of the urease and arginase to produce ammonia in the case of an l-Arg-sensing membrane and also on the hydrolysis reaction of l-Asn under the catalysis of asparaginase in the case of an l-Asn-sensing membrane. The O17-EC membrane reacted with the ammonia produced from the hydrolysis reactions and changed the fluorescence intensities at = 565 and 625 nm. The ratio of the fluorescence intensities at = 565 and 625 nm was proportional to the concentrations of l-Arg or l-Asn in the range of 0.1-10 mM. The LOD of the l-Arg- and l-Asn-sensing membranes was 0.082 ± 0.0014 and 0.074 ± 0.0023 mM, respectively. The sensing membranes also showed good quality in terms of response time, reversibility, and stability. The interference study demonstrated that some components such as amino acids had little negative effects on the performance of the sensing membranes for the detection of l-Arg and l-Asn. These simple and sensitive ratiometric fluorescent sensing membranes provide a basic or comprehensive method for detecting l-Arg and l-Asn in blood and urine samples as well as in the fermentation processes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6999337 | PMC |
http://dx.doi.org/10.1002/elsc.201700033 | DOI Listing |
Methods Appl Fluoresc
January 2025
Department of Obstetrics and Gynecology, Shengjing Hospital of China Medical University, No.36 Sanhao Street, Heping District, Shenyang, Liaoning Province, China, Shenyang, 110004, CHINA.
Molybdenum disulfide quantum dots (MoS2 QDs) is a new type of graphite like nanomaterial, which exhibited well chemical stability, unique fluorescence characteristics, and excellent biocompatibility. The conventional hydrothermal synthesis of MoS2 generally requires a long-term reaction at high temperature and high pressure. Herein, we have developed a simple and fast MoS2 QDs synthesis scheme using microwave heating, and further modified the surface of MoS2 QDs using 3-aminophenylboronic acid.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Key Laboratory of Environmental Remediation and Ecological Health, Ministry of Education, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou, 310058, China.
A sensitized dual-response ratiometric fluorescent sensor integrated smartphone platform for accurate discrimination and detection of tetracycline (TC) homologues was fabricated based on N-CDs-Eu complex. In the sensing system, N-CDs act as a sensitizer of Eu and significantly enhance the fluorescence of TC-Eu complex approximate 40-fold owing to the synergistic effect of antenna effect (AE) and fluorescence resonance energy transfer (FRET). A paper sensor integrated with a smartphone platform is further fabricated for on-site measurement of TC.
View Article and Find Full Text PDFAnal Chem
January 2025
State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun 130022, P. R. China.
Arginine (Arg) is involved in tissue metabolism and regulates the immune function; thereby, achieving the detection of Arg is crucial for early diagnosis and treatment of diseases. Herein, dual ratiometric fluorescence sensors were prepared with the blue emission of levorotatory/dextrorotatory carbon dots (CDs) and the red emission of porphyrin (L/D-CDs-PP) for the sensitive and portable detection of Arg. Interestingly, L-CDs-PP and D-CDs-PP displayed not only the dual emission peaks at 493 and 650 nm but also different response modes to Arg; thus, they could serve as dual ratiometric fluorescence sensors to achieve the accurate and reliable detection of Arg, with the detection limit of 23.
View Article and Find Full Text PDFFood Chem X
January 2025
College of Food Science and Engineering, Shanxi Agricultural University, Taiyuan, Shanxi, China.
Aiming to enable online freshness-monitoring of meat within modified-atmosphere package, we developed a ratiometric array that was fluorescently responsive to volatile organic compounds-ammonia (NH) released by protein decaying. The array was consisted of two 3 mm × 6 mm rectangles precisely and uniformly printed with fluorescein isothiocyanate (FITC) as indicator and rhodamine B (RhB) as internal reference on the filter-paper, respectively. The fluorescence intensity of the array area was calibrated according to Green/Red ratio of the digitalized pixels extracted from images facilitated by a smartphone.
View Article and Find Full Text PDFAnal Chem
January 2025
Laboratoire d'Innovation Thérapeutique, UMR7200 CNRS, Université de Strasbourg, Institut du Médicament de Strasbourg, 74 route du Rhin, Strasbourg F-67000, France.
The worldwide spread of antibiotic resistance is considered to be one of the major health threats to society. While developing new antibiotics is crucial, there is also a strong need for next-generation analytical methods for studying the physiological state of live bacteria in heterogeneous populations and their response to environmental stress. Here we report a single-cell high-throughput method to monitor changes in the bacterial cell envelope in response to stress based on ratiometric flow cytometry.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!