Differentiation of salivary gland tumors through tumor heterogeneity: a comparison between pleomorphic adenoma and Warthin tumor using CT texture analysis.

Neuroradiology

Department of Radiology, Ajou University School of Medicine, Ajou University Medical Center, 164, World Cup-ro, Yeongtong-gu, Suwon, Republic of Korea, 16499.

Published: November 2020

Purpose: We compared the diagnostic performance of CT texture analysis in single-phase CT scan with that of conventional enhancement pattern analysis in a two-phase CT scan for discrimination of salivary gland tumors, Warthin tumor (WT) from pleomorphic adenoma (PA).

Methods: One hundred seventy-eight patients with PA and 84 patients with WT were selected and CT texture analysis was separately performed on early (40s) and delayed (180s) phases, after injection of the contrast agent, using commercially available software. The attenuation changes and enhancement patterns were visually and quantitatively assessed with Hounsfield units (HU). Differences between PAs and WTs were analyzed using χ test and independent t test. Diagnostic performance of texture parameters in single-phase CT was compared with that of dynamic enhancement pattern in two-phase CT using the McNemar test.

Results: Ratio of tumoral HU (delayed phase/early phase) was significantly higher in PAs compared with WTs (p < 0.001). Tumor heterogeneity parameters, standard deviation (SD) and entropy, were significantly lower in WTs regardless of the type of filter used (p ≤ 0.001). Mean with coarse filter (AUC = 0.944) on early phase scan and entropy with medium filter (AUC = 0.901) on delayed scan were best discriminators between PAs and WTs. Diagnostic accuracy of mean (90.5%) on early scan and entropy (84.7%) on delayed scan was not significantly different from the accuracy (89.3%) of conventional wash-out pattern for distinguishing WTs from PAs (p = 0.742, p = 0.088, respectively).

Conclusion: Diagnostic performance of texture parameters was similar to that of quantitative enhancement pattern for differentiating WTs from PAs, with the advantage in lower radiation exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00234-020-02485-xDOI Listing

Publication Analysis

Top Keywords

texture analysis
12
salivary gland
8
gland tumors
8
pleomorphic adenoma
8
warthin tumor
8
diagnostic performance
8
performance texture
8
enhancement pattern
8
differentiation salivary
4
tumors tumor
4

Similar Publications

Purpose: The degenerative joint disease is a temporomandibular disorder. By analysing texture parameters, it becomes possible to characterize and differentiate various tissues, based on their textural properties according to cone-beam computed tomography (CBCT). This study evaluated degenerative diseases in the temporomandibular joint through texture analysis.

View Article and Find Full Text PDF

Enhanced detection of measurement anomalies in cartridge cases using 3D gray-level co-occurrence matrix.

Forensic Sci Int

January 2025

Department of Forensic Science and Technology, Sichuan Police College, No. 186, Longtouguan Road, Jiangyang District, Luzhou 646000, China; Sichuan Provincial Key Lab of Intelligent Policing, No. 186, Longtouguan Road, Jiangyang District, Luzhou 646000, China. Electronic address:

The firing pin impression left on the base of a cartridge case is a critical analytical feature in forensic science. To address the limitations of traditional manual trace analysis and mitigate the risk of secondary damage to physical evidence, we employ a line laser displacement sensor to capture and analyze three-dimensional (3D) traces of fired cartridge cases. However, when using laser displacement sensors to collect traces from metal cartridge cases, the high curvature and reflectivity of the metal surface can cause specular reflections, potentially leading to measurement anomalies in the firing pin impressions.

View Article and Find Full Text PDF

Background: Intraoperative ultrasound is becoming a common tool in neurosurgery. However, effective simulation methods are limited. Current, commercial, and homemade phantoms lack replication of anatomical correctness and texture complexity of brain and tumour tissue in ultrasound images.

View Article and Find Full Text PDF

This study investigated the impacts of hot water treatment (HWT) at 50°C or 25°C for 5 min and high-temperature ethylene (HTE) exposure at varying temperatures (20°C, 30°C, or 35°C) and durations (24, 48, or 72 h) on the postharvest quality and antioxidant properties of mature green tomatoes (MG). Color changes, physicochemical characteristics, antioxidant compounds, and overall antioxidant ability were assessed. HWT increased β-carotene levels and oxygen radical absorbance capacity (ORAC) while preserving color metrics, despite later HTE exposure.

View Article and Find Full Text PDF

Nanoscale Magnetic Ordering Dynamics in a High Curie Temperature Ferromagnet.

Nano Lett

January 2025

Materials Science and Technology Division, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, Tennessee 37831, United States.

Thermally driven transitions between ferromagnetic and paramagnetic phases are characterized by critical behavior with divergent susceptibilities, long-range correlations, and spin dynamics that can span kHz to GHz scales as the material approaches the critical temperature , but it has proven technically challenging to probe the relevant length and time scales with most conventional measurement techniques. In this study, we employ scanning nitrogen-vacancy center based magnetometry and relaxometry to reveal the critical behavior of a high- ferromagnetic oxide near its Curie temperature. Cluster analysis of the measured temperature-dependent nanoscale magnetic textures points to a 3D universality class with a correlation length that diverges near .

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!