A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of Acute Atmospheric Pressure Changes on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Normal Individuals: A Pilot Study. | LitMetric

Unlabelled: PRéCIS:: Intraocular pressure (IOP) measurement differences with Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) are affected by atmospheric pressure inside a hyperbaric chamber.

Purpose: To compare IOP measurements obtained with GAT and DCT in 22 normal individuals at different atmospheric pressures simulated in a hyperbaric chamber.

Methods: The IOP of both eyes of 22 healthy volunteers was measured using GAT and DCT at 4 different atmospheric pressure levels.Starting at 1 Queretaro atmospheric pressure (QATM), the IOP was measured with GAT and DCT. The atmospheric pressure was then increased to 1.1 QATM (equivalent to 1032 m above sea level), 1.2 QATM (equivalent to 315 m above sea level), and 1.25 QATM (equivalent to sea level), starting 5 minutes after reaching each level. The limits of agreement between various measurements with each tonometer were calculated using the Bland-Altman plots.

Results: The first 4 subjects were used to measure feasibility, consistency, variability, and the time needed for IOP to return to baseline after each atmospheric pressure increase.For the entire 44 eyes, the mean GAT IOP at 1 QATM was 12.23 mm Hg (range, 8 to 20 mm Hg; SD, 2.84) and mean DCT was 16.36 (range, 12.1 to 25.3; SD, 2.84), with a mean 4.14 mm Hg difference (range, -0.1 to 7.5 mm Hg; SD, 1.62; P<0.001).Using the second measurements of the first 4 subjects and those after 5 minutes of adaptation for the rest of the group at 1.1 QATM, mean GAT IOP was 11.05±2.68 mm Hg and mean DCT IOP was 15.60±3.02 mm Hg, for a mean difference between instruments of 4.56±1.81 mm Hg (P<0.001).At 1.2 QATM, mean GAT IOP was 11.14±2.53 mm Hg and mean DCT IOP was 15.39±2.91 mm Hg. The difference between instruments was 4.25±2.12 mm Hg (P<0.001).At 1.25 QATM, the mean GAT IOP was 12.39±3.11 mm Hg and mean DCT IOP was 14.91±2.73 mm Hg. The difference between instruments after 5 minutes of adaptation was 2.53±1.62 mm Hg (P<0.001).Generalized estimating equations for performing linear regression multivariable analysis using atmospheric pressure, expressed as altitude, and age as covariates, shows that the difference between GAT and DCT increases by 1 mm Hg per 673 m of increase of altitude above sea level. Age was not a significant predictor.

Conclusions: Acute changes in atmospheric pressure induce changes in IOP measurements for both GAT and DCT and in different directions. Despite the limitation of sample size, it may be postulated that the difference of IOP measurements between the 2 tonometers increases with lower atmospheric pressures.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000001592DOI Listing

Publication Analysis

Top Keywords

atmospheric pressure
24
dct atmospheric
12
gat dct
12
sea level
12
dynamic contour
8
contour tonometry
8
goldmann applanation
8
applanation tonometry
8
normal individuals
8
measured gat
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!