A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental design and RSM on the recovery of Ni (II) ions by ELM using TX-100 as a biodegradable surfactant. | LitMetric

The present work deals with the extraction and pre-concentration of nickel (II) ions using emulsified liquid membrane (ELM) in the presence of di- (2-ethylhexyl) phosphoric acid (D2EHPA) as an extractant. The emulsion stability was achieved by the biodegradable surfactants Triton X-100 addition diluted in kerosene. Influence of operating conditions that affect ELM performance were investigated. A comparative study between the optimization parameters of this process was carried out both experimentally and with the Response Surface Methodology (RSM), in accordance with the Box-Behnken matrix. The following parameters were investegated: D2EHPA / Triton X-100 ratio between 0.5 and 3.5, initial concentration of the feed phase between 200 and 500 ppm and pH of the feed phase from 2.5-10. The transport of Ni (II) ions was evaluated according to the extraction yield as an analytical response and the optimal conditions were determined. It was found that the calculated values being in good agreement with experimental data that under the optimized conditions ([Ni] = 350 ppm, Vagitation = 200 rpm,  = 20 min and pH = 6.6), Ni (II) ions extraction was recorded more than 94% of efficiency.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09593330.2020.1791967DOI Listing

Publication Analysis

Top Keywords

triton x-100
8
feed phase
8
experimental design
4
design rsm
4
rsm recovery
4
ions
4
recovery ions
4
ions elm
4
elm tx-100
4
tx-100 biodegradable
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!