Certain individuals tend to suffer from a cold sensation-particularly in the lower extremities-despite most people not suffering from the same sensation. In Japan, this phenomenon is called "hie-sho" and reduces quality of life for several people, particularly women. A previous study has shown that a standardized oligomerized-polyphenol from Litchi chinensis fruit extract (OPLFE) reportedly causes a significant increase in body surface temperature. The present study aimed to investigate whether supplementation with OPLFE affected peripheral circulation and cold sensitivity. This randomized, double-blind, placebo-controlled trial was performed including 25 participants (age, 45.0±10.4 y; 3 males and 22 females) who were assigned to consume OPLFE, mixed plant extract with OPLFE, or placebo capsules for 14 d. Participants were instructed to relax for 60 min in a temperature-controlled room prior to obtaining measurements. Changes in skin temperature and peripheral blood flow of the middle finger were assessed immediately before and 1, 5, 10, 20, and 30 min after immersion in cold water (10ºC). Participants' height, weight, skin temperature, and blood flow in peripheral tissue were measured; furthermore, their "hie-sho" was measured using the Visual Analog Scale (VAS). Skin temperature and blood flow in peripheral tissue increased in the OPLFE and mixed plant extract with OPLFE groups on day 14 compared with those on day 1. In addition, cold sensitivity in these two groups significantly improved between day 1 and day 14. These findings suggest that OPLFE improves "hie-sho" by increasing peripheral blood flow and skin temperature.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3177/jnsv.66.255 | DOI Listing |
Innovation (Camb)
September 2024
Department of Materials Science and Engineering, Southern University and Science and Technology, Shenzhen 518055, China.
The human skin maintains a comfortable and healthy somatosensory state by sensing different aspects of the thermal environment, including temperature value, heat source, energy level, and duration. However, state-of-the-art thermosensors only measure basic temperature values, not the full range of the thermosensation function of human skin. Here, we propose a heat source recognition () sensor of poly(butyl acrylate)-lithium bis(n-fluoroalkylsulfonyl)imide (PBA-Li:FSI; = 1, 3, 5), which enables response to temperature, pressure, and proximity stimulus signals based on the relaxation behavior of the ionic gel and distinguished between different types of heat sources (i.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Key Laboratory of Organic Optoelectronics and Molecular Engineering and Laboratory of Flexible Electronics Technology, Department of Chemistry, Tsinghua University, Beijing 100084, P. R. China.
Wearable temperature-sensitive electronic skin enables robots to rapidly detect environmental changes and respond intelligently, thereby reducing temperature-related mechanical failures. Additionally, this temperature-sensitive skin can measure and record the temperature of external objects, broadening its potential applications in the medical field. In this study, we designed a thermally sensitive artificial ionic skin using ionic liquids (ILs) as solvents and carbon nanotubes (CNTs) as thermally conductive fillers.
View Article and Find Full Text PDFPhysiol Behav
January 2025
School of Mechanical Engineering, Tongji University, Shanghai, China; Institute for Environmental Design and Engineering, University College London, UK.
The ageing population has increased the attention on care services for older people, particularly concerning their health and thermal comfort. However, most existing studies focus on the overall thermal comfort of older people, with insufficient research into their local thermal needs for different body parts, impeding precise thermal adjustments and optimal thermal satisfaction. This study investigated the local thermal comfort and skin temperature of older people under various environmental conditions.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Surgical Sciences, University of Wisconsin, Madison, Wisconsin, United States of America.
Temperature regulation in dogs is significantly impaired during general anesthesia. Glabrous skin on paws may facilitate thermoregulation from this area and is a potential target for interventions attenuating hypothermia. This pilot study aimed to compare efficacy of an innovative warming device placed on the front paws (AVAcore; AVA), with no warming methods (NONE) and conventional truncal warming methods (CONV; circulating water blanket/forced air warmer) on rectal temperature and anesthetic recovery times.
View Article and Find Full Text PDFTurk J Emerg Med
January 2025
Department of Emergency Medicine, Travancore Medical College Hospital, Kollam, Kerala, India.
Introduction: The initial 24-h period following admission to a hospital holds profound significance for pediatric patients, representing a critical window where proactive interventions can substantially influence outcomes. We devised a simple triage system, pediatric simple triage score (PSTS), to see whether rapid triage of sick pediatric patients with fever can be done using the new triage system in the emergency department (ED) to predict hospital admission.
Methods: This was a prospective observational study, conducted at the department of emergency medicine of a tertiary care teaching hospital in southern India.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!