We first studied the distribution of radioactivity during continuous inhalation of C15O2 and 15O2 in traverse tomograms of the greatest diameter of legs, at rest and immediately after exercise (ankle flexions). C15O2 and 15O2 were distributed homogeneously and symmetrically in both legs of normal subjects at rest. The activity accumulated in the anterolateral region after exercise. In patients, this pattern of distribution was similar but asymmetrical, depending on the arterial pathology. No systematic distribution of either C15O2 or 15O2 was observed. In a second step, we studied quantitatively blood flow (F), oxygen uptake (R) and oxygen extraction (E) in 11 subjects: 5 normals (23 +/- 1 years) and 6 patients (60 +/- 11 years) suffering from unilateral intermittent claudication. We used the bolus inhalation technique of C15O2 and 15O2. In the normal leg at rest, ranges were 2.5 to 8.0 ml/min.hg for F, 0.9 to 21.3 mumol/min.hg for R and 3.6 to 33.4% for E. In the pathological leg at rest, ranges were 3.7 to 11.3 ml/min.hg for F, 3.8 to 10.6 mumol/min.hg for R and 7.1 to 24.5% for E. After exercise, ranges were 6.4 to 62.8 ml/min.hg for F, 66.0 to 386.3 mumol/min.hg for R and 29.2 to 89.5% for E in both legs. There was no straight difference between normal and pathological legs soon after exercise. This study allows us to expect that the demonstration of such a difference implies a longer delay of data acquisition following the slow post-ischemia recovery.
Download full-text PDF |
Source |
---|
J Cereb Blood Flow Metab
August 2024
Department of Neurosurgery, National Cerebral and Cardiovascular Center, Osaka, Japan.
Ann Nucl Med
April 2021
Department of Radiology and Nuclear Medicine, Fukushima Medical University, 1 Hikariga-oka, Fukushima, 960-1295, Japan.
Objectives: Measurement of cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO) by PET with oxygen-15 labeled gases is useful for diagnosis and treatment planning in cases of chronic occlusive cerebrovascular disease. In the present study, CBF, CBV, OEF and CMRO were measured using the integrated design of PET/MRI scanner system. This is a first attempt to measure cerebral perfusion and oxygen metabolism using PET/MRI with oxygen-15 labeled gases.
View Article and Find Full Text PDFEJNMMI Phys
December 2018
Department of Radiology, National Cerebral and Cardiovascular Center, 5-7-1 Fujishiro-dai, Suita, Osaka, 565-8565, Japan.
Background: O-oxygen inhalation PET is unique in its ability to provide fundamental information regarding cerebral hemodynamics and energy metabolism in man. However, the use of O-oxygen has been limited in a clinical environment largely attributed to logistical complexity, in relation to a long study period, and the need to produce and inhale three sets of radiopharmaceuticals. Despite the recent works that enabled shortening of the PET examination period, radiopharmaceutical production has still been a limiting factor.
View Article and Find Full Text PDFJ Nucl Med
December 2017
Department of Nuclear Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
In 3-dimensional PET/CT imaging of the brain with O-gas inhalation, high radioactivity in the face mask creates cold artifacts and affects the quantitative accuracy when scatter is corrected by conventional methods (e.g., single-scatter simulation [SSS] with tail-fitting scaling [TFS-SSS]).
View Article and Find Full Text PDFJ Cereb Blood Flow Metab
May 2018
Department of Radiology, Kagawa University, Kagawa, Japan.
CBF, OEF, and CMRO images can be quantitatively assessed using PET. Their image calculation requires arterial input functions, which require invasive procedure. The aim of the present study was to develop a non-invasive approach with image-derived input functions (IDIFs) using an image from an ultra-rapid O and CO protocol.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!