Results of the Insertion of Hysteroscopic Sterilization Devices in a Brazilian Public Hospital.

Rev Bras Ginecol Obstet

Department of General Surgery ad Specialty, Universidade Federal Fluminense, Niterói, RJ, Brazil.

Published: June 2020

Objective:  To evaluate the insertion of the hysteroscopic intratubal sterilization device for female sterilization concerning the technique and the feasibility.

Methods:  Retrospective study with data collection of medical records of 904 patients who underwent device insertion between January and September 2016 in a public hospital in Rio de Janeiro (Brazil) with data analysis and descriptive statistics.

Results:  In 85.8% of the cases, the uterine cavity was normal, and the most commonly-described findings upon hysteroscopy were synechiae (9.5%). The procedure lasted an average of 3.56 minutes (range: 1 to 10 minutes), and the pain was considered inexistent or mild in 58,6% of the cases, mild or moderate in 32,8%, and severe or agonizing in less than 1% (0.8%) of the cases, based on a verbal scale ranging from 0 to 10. The rate of successful insertions was of 85.0%, and successful tubal placement was achieved in 99.5% of the cases. There were no severe complications related to the procedure, but transient vasovagal reactions occurred in 5 women (0.6%).

Conclusion:  Female sterilization performed by hysteroscopy is a safe, feasible, fast, and well-tolerated procedure. The rates of successful insertions and tubal placements were high. There were few and mild adverse effects during the procedure, and there were no severe complications on the short term.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10418143PMC
http://dx.doi.org/10.1055/s-0040-1712129DOI Listing

Publication Analysis

Top Keywords

insertion hysteroscopic
8
public hospital
8
successful insertions
8
severe complications
8
sterilization
4
hysteroscopic sterilization
4
sterilization devices
4
devices brazilian
4
brazilian public
4
hospital objective
4

Similar Publications

Background Hysteroscopy, a minimally invasive procedure for diagnosing and treating intrauterine pathologies, can be challenging due to inadequate cervical dilation, leading to procedural difficulties and patient discomfort. Misoprostol, a synthetic prostaglandin E1 analog, is increasingly used for cervical ripening to ease hysteroscopic procedures. Objective To evaluate the efficacy and safety of misoprostol for cervical ripening prior to hysteroscopy.

View Article and Find Full Text PDF

Study Objective: We present the results of the first feasibility and safety study of a novel multi-modality falloposcope, in 19 volunteers. The falloposcope incorporated multispectral fluorescence imaging (MFI) and optical coherence tomography (OCT) for evaluation of the fallopian tubes (FT).

Methods: Nineteen females undergoing elective salpingectomy were recruited in this IRB-approved study.

View Article and Find Full Text PDF

This is the case of a 30-year-old nulliparous patient with a complete uterine septum, double cervix and non- obstructive longitudinal vaginal septum (Class U2bC2V1 according to the ESHRE/ESGE classification). The patient presented with severe dyspareunia and dysmenorrhea. Imaging revealed a complex Müllerian anomaly and hysteroscopic treatment was agreed.

View Article and Find Full Text PDF

Hysteroscopy is an endoscopic diagnostic and therapeutic method traditionally performed under general anesthesia but increasingly under local anesthesia. Today, it is considered the gold standard in gynecology. This minimally invasive procedure allows for a detailed assessment of the uterine cavity's interior and the removal of abnormal changes within it and is applicable to patients of all ages.

View Article and Find Full Text PDF

Background: This study aimed to investigate the safety and efficacy of suture fixation of the levonorgestrel-releasing intrauterine device (LNG-IUD) by hysteroscope for the treatment of adenomyosis in patients at high risk of device expulsion, to provide a viable treatment option for these patients.

Methods: Twenty-one patients with large symptomatic adenomyosis were sewed and fixed with the LNG-IUD in the uterus by hysteroscopy to prevent the device expulsion.

Results: In this prospective case series, all 21 patients were successfully sewed and fixed with the LNG-IUD in the uterus by hysteroscopy.