Objectives: Coronary sinus (CS) based mitral annuloplasty using the Carillon device is effective in reducing functional mitral valve regurgitation (FMR). However, this positive effect might be dependent on the relation between CS and the mitral annulus.

Background: Computed tomography (CT) assessment prior to mitral valve interventions is an emerging technique to optimize patient selection.

Methods: In a retrospective analysis 30 patients underwent Carillon device implantation and received CT-angiography prior to CS based percutaneous mitral valve repair. Patients were assigned to responders or non-responders according to the 3-month transthoracic echocardiographic follow-up including quantitative mitral valve regurgitation assessment. A prototype software for CS reconstruction was used to assess distance and angle of both CS and mitral annulus planes.

Results: Comparison of the distance and angle of the CS plane and the mitral valve annulus plane showed a significant shorter distance and lower angle in the responder group implicating an impact on procedure success. Our results suggest a CS plane and MV annulus plane with a favorably distance of <7.8 mm and an optimal angle of <14.2° could be considered favorably for mitral annuloplasty using a Carillon device.

Conclusions: Distance and angle of mitral annulus and CS planes determined by three-dimensional reconstructions of CT-angiography might predict a reduction in echocardiographic FMR using Carillon Mitral Contour System.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.29107DOI Listing

Publication Analysis

Top Keywords

mitral valve
20
mitral
10
mitral annuloplasty
8
functional mitral
8
carillon device
8
valve regurgitation
8
distance angle
8
annulus plane
8
valve
5
ct-angiography predict
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!