A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Commercialization challenges for drug eluting contact lenses. | LitMetric

Introduction: Eye drops are commonly used for delivering ophthalmic drugs despite many deficiencies including low bioavailability and poor compliance. Contact lenses can deliver drugs with high bioavailability but commercial contacts release drug rapidly, limiting benefits and necessitating modifications to improve the drug release characteristics.

Areas Covered: This review covers the common approaches to prolong the release rates of drugs from contact lenses including molecular imprinting, incorporation of nano/microparticles, vitamin-E barriers, and layered/implant contact lenses. It also evaluates their suitability for commercialization and discusses challenges that need to be addressed before commercialization is possible.

Expert Opinion: In spite of many benefits of contact lenses compared to eye drops, a drug-eluting contact lens has not emerged in the market due to many reasons including potential safety risks, patient and practitioner acceptance, and production and storage factors. Importantly, changes in the critical lens properties must also be considered such as ion and oxygen permeability, loss in modulus, optical and swelling properties, and protein adherence upon drug loading. Many technologies have addressed scientific and commercialization challenges and are currently being tested both in animal and clinical studies. It is likely that a drug-eluting contact lens will be commercialized in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1080/17425247.2020.1787983DOI Listing

Publication Analysis

Top Keywords

contact lenses
20
commercialization challenges
8
eye drops
8
drug-eluting contact
8
contact lens
8
contact
7
lenses
5
commercialization
4
drug
4
challenges drug
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!