Background: Two novel methods of image reconstruction, xSPECT Quant (xQ) and xSPECT Bone (xB), that use an ordered subset conjugate gradient minimizer (OSCGM) for SPECT/CT reconstruction have been proposed. The present study compares the performance characteristics of xQ, xB, and conventional Flash3D (F3D) reconstruction using images derived from phantoms and patients.
Methods: A custom-designed body phantom for bone SPECT was scanned using a Symbia Intevo (Siemens Healthineers), and reconstructed xSPECT images were evaluated. The phantom experiments proceeded twice with different activity concentrations and sphere sizes. A phantom with 28-mm spheres containing a Tc-background and tumor-to-normal bone ratios (TBR) of 1, 2, 4, and 10 were generated, and convergence property against various TBR was evaluated across 96 iterations. A phantom with four spheres (13-, 17-, 22-, and 28-mm diameters), containing a Tc-background at TBR4, was also generated. The full width at half maximum of an imaged spinous process (10 mm), coefficients of variance (CV), contrast-to-noise ratio (CNR), and recovery coefficients (RC) were evaluated after reconstructing images of a spine using Flash 3D (F3D), xQ, and xB. We retrospectively analyzed images from 20 patients with suspected bone metastases (male, n = 13) which were acquired using [Tc]Tc-(H)MDP SPECT/CT, then CV and standardized uptake values (SUV) at the 4 vertebral body (L4) were compared after xQ and xB reconstruction in a clinical setup.
Results: Mean activity concentrations with various TBR converged according to increasing numbers of iterations. The spatial resolution of xB was considerably superior to xQ and F3D, and it approached almost the actual size regardless of the iteration numbers during reconstruction. The CV and RC were better for xQ and xB than for F3D. The CNR peaked at 24 iterations for xQ and 48 iterations for F3D and xB, respectively. The RC between xQ and xB significantly differed at lower numbers of iterations but were almost equivalent at higher numbers of iterations. The reconstructed xQ and xB images of the clinical patients showed a significant difference in the SUV and SUV.
Conclusions: The reconstructed xQ and xB images were more accurate than those reconstructed conventionally using F3D. The xB for bone SPECT imaging offered essentially unchanged spatial resolution even when the numbers of iterations did not converge. The xB reconstruction further enhanced SPECT image quality using CT data. Our findings provide important information for understanding the performance characteristics of the novel xQ and xB algorithms.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7324467 | PMC |
http://dx.doi.org/10.1186/s13550-020-00659-5 | DOI Listing |
Alzheimers Dement
December 2024
Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Background: Clinical trials should strive to yield results that are clinically meaningful rather than solely relying on statistical significance. However, the determination of clinical meaningfulness of dementia clinical trials lacks standardization and varies based on the trial's nature. To tackle this issue, a proposed approach involves assessing the time saved before reaching a specific threshold in cognitive status.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Indiana University School of Medicine, Indianapolis, IN, USA.
Background: Screening for cognitive impairment in primary care faces challenges, including time constraints, provider apprehension, and limited diagnostic confidence. An effective initiative for improving screening must include strategies to foster behavioral change, and active provider engagement. Agile implementation science integrates findings from behavioral economics, complexity science, and network science, to address these challenges by confirming the demand to solve the problem; local solution adaptation; and the iterative 'sprints', or tests of change, that are focused on execution.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Nuclear Medicine and Medical Physics, Karolinska University Hospital, Stockholm, Sweden.
Background: Modern reconstruction algorithms for computed tomography (CT) can exhibit nonlinear properties, including non-stationarity of noise and contrast dependence of both noise and spatial resolution. Model observers have been recommended as a tool for the task-based assessment of image quality (Samei E et al., Med Phys.
View Article and Find Full Text PDFBMJ Open Gastroenterol
January 2025
Inflammatory Bowel Disease Center and Division of Gastroenterology and Hepatology, Cedars-Sinai Medical Center, Los Angeles, California, USA.
Objective: Etrasimod is an oral, once-daily, selective sphingosine 1-phosphate (S1P) receptor modulator for the treatment of moderately to severely active ulcerative colitis (UC). S1P receptor expression on cardiac cells is involved in cardiac conduction. We report cardiovascular treatment-emergent adverse events (TEAEs) associated with S1P receptor modulators and other cardiovascular events in the etrasimod UC clinical programme.
View Article and Find Full Text PDFNeuroinformatics
January 2025
Neuro Electronics Res. Flanders (NERF), Heverlee, 3001, Belgium.
Neuropixels probes contain thousands of electrodes across one or more shanks and are sufficiently small to allow chronic recording of neural activity in freely behaving small animals. However, the joint increase in the number of electrodes and miniaturization of the probe package has led to a compromise in which groups of electrodes share a single read-out channel and only a fraction of the electrodes can be read out at any given time. Experimenters then face the challenge of selecting a subset of electrodes (i.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!