A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Neck modularity in total hip arthroplasty: a retrospective study of nine hundred twenty-eight titanium neck implants with a maximum follow-up of eighteen years. | LitMetric

Purpose: Neck modularity was introduced to improve total hip arthroplasty (THA) accuracy, but it has been associated with early breakages and corrosion issues. In our hospital, modular necks have been in clinical use since the 1990s. We retrospectively analysed the occurrence of these sequelae in implants placed between January 2000 and December 2014.

Methods: Survival data from patients operated on in our hospital were obtained from the regional arthroplasty registry (Registro dell'Impiantologia Protesica Ortopedica, RIPO). The cohort comprised 928 THAs on 908 patients. The average patient age was 67.8 years. Main indications were primary osteoarthritis (71.4%), fracture (9.2%), congenital dysplasia or congenital luxation (7.8%), and idiopathic osteonecrosis (6.4%). All femoral stems were cementless, with 318 anatomically shaped (34.3%), 579 straight (62.4%), and 31 short stems (3.3%). All necks used were made of titanium alloy. The average follow-up time was 9.6 years (range, 4-18 years).

Results: In total, 66 revisions were reported. The main revision causes were periprosthetic fractures (33.3%), aseptic stem loosening (19.7%), luxation (18.2%), and implant breakage (12.1%). Five modular neck breakages were recorded. The overall survival rate was 87.7% at 17 years. We did not observe any component corrosion. The neck breakage rate was 0.5%, and the luxation rate was 1.3%.

Conclusions: Our experience suggests that neck modularity is a safe, effective way to reconstruct the proximal femur in THA patients. We attribute the absence of corrosion to the exclusive use of titanium necks.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-020-04686-8DOI Listing

Publication Analysis

Top Keywords

neck modularity
12
total hip
8
hip arthroplasty
8
neck
6
modularity total
4
arthroplasty retrospective
4
retrospective study
4
study twenty-eight
4
twenty-eight titanium
4
titanium neck
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!