Aims: Dual mobility (DM) bearings are an attractive treatment option to obtain hip stability during challenging primary and revision total hip arthroplasty (THA) cases. The purpose of this study was to analyze data submitted to the American Joint Replacement Registry (AJRR) to characterize utilization trends of DM bearings in the USA.

Methods: All primary and revision THA procedures reported to AJRR from 2012 to 2018 were analyzed. Patients of all ages were included and subdivided into DM and traditional bearing surface cohorts. Patient demographics, geographical region, hospital size, and teaching affiliation were assessed. Associations were determined by chi-squared analysis and logistic regression was performed to assess outcome variables.

Results: A total of 406,900 primary and 34,745 revision THAs were identified, of which 35,455 (8.7%) and 8,031 (23.1%) received DM implants respectively. For primary THA, DM usage increased from 6.7% in 2012 to 12.0% in 2018. Among revision THA, DM use increased from 19.5% in 2012 to 30.6% in 2018. Patients < 50 years of age had the highest rates of DM implantation in every year examined. For each year of increase in age, there was a 0.4% decrease in the rate of DM utilization (odds ratio (OR) 0.996 (95% confidence interval (CI) 0.995 to 0.997); p < 0.001). Females were more likely to receive a DM implant compared to males (OR 1.077 (95% CI 1.054 to 1.100); p < 0.001). Major teaching institutions and smaller hospitals were associated with higher rates of utilization. DM articulations were used more commonly for dysplasia compared with osteoarthritis (OR 2.448 (95% CI 2.032 to 2.949); p < 0.001) during primary THA and for instability (OR 3.130 (95% CI 2.751 to 3.562) vs poly-wear; p < 0.001) in the revision setting.

Conclusion: DM articulations showed a marked increase in utilization during the period examined. Younger patient age, female sex, and hospital characteristics such as teaching status, smaller size, and geographical location were associated with increased utilization. DM articulations were used more frequently for primary THA in patients with dysplasia and for revision THA in patients being treated for instability. Cite this article: 2020;102-B(7 Supple B):27-32.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.102B7.BJJ-2019-1669.R1DOI Listing

Publication Analysis

Top Keywords

revision tha
12
primary tha
12
dual mobility
8
mobility bearings
8
hip arthroplasty
8
primary revision
8
utilization articulations
8
tha patients
8
tha
7
primary
6

Similar Publications

Purpose: Studies evaluating the long-term survival rate, patient satisfaction, and conversion to total hip arthroplasty (THA) are limited. The aim of this study was to evaluate satisfaction and hip survival at a minimum 10-year follow-up in patients following hip arthroscopy for femoroacetabular impingement syndrome (FAIS).

Methods: A total of 164 patients underwent hip arthroscopy for FAIS between 2007 and 2012; of these, 76 (49 men and 27 women; mean age, 40.

View Article and Find Full Text PDF

The 'Japanese paradox' of total hip arthroplasty: where are we going?

Expert Rev Med Devices

January 2025

Department of Orthopaedic Surgery, Kansai Medical University, Hirakata, Osaka, Japan.

Introduction: There is a worldwide trend toward 'revisiting' cemented total hip arthroplasty (THA). In Japan, however, cemented THAs accounts for 11%, and the percentage of cemented hemiarthroplasty is estimated to be less than 10%. This review was designed to reconsider the option of cemented THA and to encourage policy changes in Japan to support the best possible care for patients.

View Article and Find Full Text PDF

Aims: Dislocation is a major concern following total hip arthroplasty (THA) for osteoarthritis (OA). Both dual-mobility components and standard acetabular components with large femoral heads are used to reduce the risk of dislocation. We investigated whether dual-mobility components are superior to standard components in reducing the two-year dislocation and revision risk in a propensity-matched sample from the Danish Hip Arthroplasty Register (DHR).

View Article and Find Full Text PDF

Aims: The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems.

View Article and Find Full Text PDF

Background: Jehovah's Witness patients refuse blood transfusion because of their religious beliefs making total hip arthroplasty (THA) challenging. This study aims to determine the safety of THA in Jehovah's Witness patients using standard perioperative protocols as well as evaluate the effectiveness of tranexamic acid (TXA) in controlling blood loss.

Methods: Databases from two tertiary academic centers were queried from 2003 to 2021 to identify THA patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?