We report a mid-IR transmission setup for the analysis of the protein amide I and amide II band in aqueous solutions that achieves a limit of detection as low as 0.0025 mg mL (outperforming our previous results and other state-of-the-art mid-IR-based techniques by almost an order of magnitude). This large improvement is made possible by combining the latest-generation external cavity-quantum cascade laser (EC-QCL) operated at room temperature with an optimized double-beam optical setup that adjusts the path length (26 μm) to ensure robust sample handling. For minimizing the noise introduced by the high-intensity laser light source, a thermoelectrically cooled mercury cadmium telluride balanced detection module was employed. In this way, noise levels better by a factor of up to 20 were achieved compared with single-channel measurements. Characteristic spectral features of proteins with different secondary structures were successfully identified at concentrations as low as 0.1 mg mL. Furthermore, a highly linear response was demonstrated for concentrations between 0.05 and 10 mg mL. The total acquisition time of the setup can be adapted to fulfill the required sensitivity of the protein measurements and to ensure maximum flexibility for future applications. The presented setup combines high sensitivity, large optical path lengths, and short measurement times and thus outperforms previous research type EC-QCL setups as well as commercially available instruments. This opens a wide range of future applications including protein-ligand interaction studies as well as qualitative and quantitative analyses of proteins in complex matrices such as those found in up- and downstream bioprocess monitoring and similar challenging applications which can not be readily met by conventional FT-IR spectroscopy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7376528 | PMC |
http://dx.doi.org/10.1021/acs.analchem.0c01406 | DOI Listing |
Langmuir
December 2024
Department of Chemical and Biological Sciences S.N. Bose National Centre for Basic Sciences Block-JD, Sector-III, Salt Lake Kolkata-700106, India.
We report an instantaneous room-temperature phase separation of 1 mM bovine serum albumin solution in the presence of (20% acetic acid+0.2 M NaCl), a routinely used food preservative; an opaque liquid-like phase (L) coexists in equilibrium with a granular gel like phase (G). Interestingly, neither 20% acetic acid nor 0.
View Article and Find Full Text PDFACS Appl Opt Mater
September 2024
Institute of Chemical Technologies and Analytics, TU Wien, Getreidemarkt 9, 1060 Wien, Austria.
Alignment tolerant coupling interfaces are an important feat for mid-IR waveguides when moving closer to real-world sensing applications, as they allow for an easy and fast replacement of waveguides. In this work, we demonstrate the alignment tolerant behavior of a germanium-on-silicon trenched waveguide platform with monolithically integrated microlenses using backside coupling of an expanded beam for evanescent field sensing between 6.5 and 7.
View Article and Find Full Text PDFWe report a 4.3 µm mid-infrared (mid-IR) high-power amplified spontaneous emission (ASE) fiber source based on CO-filled nested hollow-core anti-resonant fiber (Nested HC-ARF). The pump source is a homemade hundred-watt-level wavelength-tunable 2 µm single-frequency fiber laser.
View Article and Find Full Text PDFACS Nano
June 2024
Department of Mechanical Engineering, College of Design and Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117575, Singapore.
Surface phonon polaritons (SPhPs) originate from the coupling of mid-IR photons and optical phonons, generating evanescent waves along the polar dielectric surface. The emergence of SPhPs gives rise to a phase of quantum matter that facilitates long-range energy transfer (100s μm-scale). Albeit of the recent experimental progress to observe the enhanced thermal conductivity of polar dielectric nanostructures mediated by SPhPs, the potential mechanism to present the high thermal conductivity beyond the Landauer limit has not been addressed.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
August 2024
Institute of Molecular Science, Universitat de València, 46980 Paterna, Spain. Electronic address:
Absorption spectra of aqueous samples measured by transmission need to be acquired using very thin cells (5-50 μm) when targeting the mid-infrared (mid-IR) region due to the strong background absorbance of liquid water. The thickness of the cell used controls the pathlength of the light through the sample, a value needed to transform absorption spectra into molar absorption coefficient spectra, or to determine solute concentrations from absorption spectra. The most accurate way to determine the thickness of an empty cell (i.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!