A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Treatment Method and Results of Percutaneous Pinning and Dynamic External Fixator Application for Unstable Distal Radius Fractures. | LitMetric

Objective: The aim of the present study was to present the results of patients with unstable distal radius fracture treated with closed reduction and percutaneous fixation followed by application of the Pennig dynamic wrist fixator to allow early wrist motion.

Methods: Twenty-five patients diagnosed with distal radius fracture and treated with closed reduction and percutaneous fixation followed by application of a dynamic wrist fixator were included in the study. There were 15 (60%) male and 10 (40%) female patients. The mean age of the patients was 47.32 (20-76) years. The mean period between initial trauma and operation was 8.52 (1-23) days. All patients were allowed active shoulder, elbow, and finger exercises immediately after surgery.

Results: Radiological evaluation was performed according to the criteria described by Sarmiento and modified by Lidström. Results were excellent in 12 (46.15%), good in 11 (42.30%), and fair in 3 (11.55%) patients. No patient had poor result. Functional scores were assessed according to the Gartland-Werley classification and modified by Sarmiento. Results were excellent in 14 (56%), good in 8 (32%), and moderate in 3 (12%) patients.

Conclusion: Use of the Pennig dynamic wrist fixator in the treatment of unstable distal radius fractures has advantages, such as ease of use, minimal surgical trauma, allowing early rehabilitation, and early return to daily activities as well as increased anatomical and functional results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7315085PMC
http://dx.doi.org/10.14744/SEMB.2018.07078DOI Listing

Publication Analysis

Top Keywords

distal radius
16
unstable distal
12
dynamic wrist
12
wrist fixator
12
radius fractures
8
radius fracture
8
fracture treated
8
treated closed
8
closed reduction
8
reduction percutaneous
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!