Background Context: Mathematical modeling for creating computer spine models is one of the basic methods underlying many scientific publications. The accuracy of strength parameters of tissues introduced into such models translates directly into the reliability of obtained results. Experimental determination of Young's modulus (E) in various areas of spongy bone tissue seems to be crucial for creating a reliable spine model without excessive simplifications in the form of a single E value for the whole vertebral body.
Purpose: The aim of the study was to determine Young's modulus in different parts of the lumbar vertebral column for samples subjected to compression and bending.
Study Design: Cylindrical spongy bone tissue samples were subjected to bending and compression strength tests.
Methods: The study included 975 pathologically unchanged samples of spongy bone tissue harvested from the lumbar vertebrae of 15 male donors. The samples were subjected to compression or bending strength tests and then Young's modulus was determined for each sample depending on its location in the vertebral body. The samples were tested differently between given locations within one vertebra as well as between vertebrae.
Results: Compressed specimens are characterized by highly significantly different Young's modulus values depending on the location in the vertebral body. Samples No. 7 and No. 9 in the anterior part of the vertebral body have highly significantly higher Young's modulus values compared to those in the posterior part of the vertebral body for all lumbar vertebrae. Samples subjected to bending showed significant differences (p<.05) between samples located closer to the vertebral canal (No.16, No.17) and samples located further away (No.14, No.15) with higher values for the samples located in the posterior part of the vertebral body.
Conclusions: Accommodating the anisotropic structure of spongy bone in computer models and the application of different Young's module values for areas within one vertebral body will allow one to obtain realistic results of computer simulations used.
Clinical Significance: Determining the exact strength parameters of spongy bone tissue within one vertebra and changes in these properties in subsequent vertebrae will allow to create more accurate computer models of the lumbar spine and the whole spine. This, in turn, will translate into more reliable computer simulations used, among others, to determine the risk of fractures or osteoporotic changes, or simulation of the procedure of spinal fusion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.spinee.2020.06.013 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu 610065, China.
The ongoing soft actuation has accentuated the demand for dielectric elastomers (DEs) capable of large deformation to replace the traditional rigid mechanical apparatus. However, the low actuation strain of DEs considerably limits their practical applications. This work developed high-performance polyurethane-urea (PUU) elastomers featuring large actuation strains utilizing an approach of kinetic control over the microphase separation structure during the fabrication process.
View Article and Find Full Text PDFMed Biol Eng Comput
January 2025
Department of Biomedical Engineering, Indian Institute of Technology, Ropar, Punjab, India.
Blood pressure (BP) is one of the vital physiological parameters, and its measurement is done routinely for almost all patients who visit hospitals. Cuffless BP measurement has been of great research interest over the last few years. In this paper, we aim to establish a method for cuffless measurement of BP using ultrasound.
View Article and Find Full Text PDFJ Vis Exp
December 2024
School of Engineering and Materials Science, Queen Mary University of London.
Under current minimally invasive treatment regimes, minor tooth preparation and thinner biomimetic ceramic restoration are used to preserve the restored tooth's vitality, aesthetics, and function. New computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic-like material are now available. To guarantee longevity, a dental clinician must know these newly launched product's mechanical strength compared to the relatively brittle glass-matrix ceramic.
View Article and Find Full Text PDFHeliyon
December 2024
Research Laboratory for Biomechanics and Implant Technology, Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany.
Subject-specific finite element (FE) modeling of the mandible bone has recently gained attention for its higher accuracy. A critical modeling factor is including personalized material properties from medical images especially when bone quality has to be respected. However, there is no consensus on the material model for the mandible that realistically estimates the Young's modulus of the bone.
View Article and Find Full Text PDFFront Oncol
December 2024
Department of Medical Ultrasound, China Resources & Wisco General Hospital, Wuhan University of Science and Technology, Wuhan, China.
Objectives: Shear-wave elastography (SWE) provides valuable stiffness within breast masses, making it a useful supplement to conventional ultrasound imaging. Super-resolution ultrasound (SRUS) imaging enhances microvascular visualization, aiding in the differential diagnosis of breast masses. Current clinical ultrasound diagnosis of breast cancer primarily relies on gray-scale ultrasound.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!