A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Frequency Responses of Conventional and Amplified Stethoscopes for Measuring Heart Sounds. | LitMetric

Frequency Responses of Conventional and Amplified Stethoscopes for Measuring Heart Sounds.

Saudi J Med Med Sci

The Speech and Hearing Center, School of Communication, Louisiana Tech University, Ruston, Louisiana, USA.

Published: April 2020

Background: Frequencies of normal and abnormal heart sounds have previously been reported, but the acoustic analyses of the frequency responses of conventional and amplified stethoscopes for different heart sounds have not yet been reported.

Objectives: To compare the acoustic analysis of frequency responses of three stethoscopes (conventional and amplified) for measuring simulated heart sounds.

Materials And Methods: This exploratory study used Starkey SLI-ST3, Cardionics E-Scope II (both electronic) and Littmann Classic S.E. II (conventional) stethoscopes, as they share the same basic design with twin ear tubes coupled to ear tips and chest piece options (bell vs. diaphragm modes). Acoustic analyses using the diaphragm were performed in a soundproof booth and frequency response curves at 85 (the largest), 250, 400, 550 and 1050 Hz were compared for three different digitized heart sound simulations: normal, aortic valvular stenosis (AVS) and pulmonic valvular stenosis.

Results: Amplified stethoscopes provided the most amplification of normal and abnormal heart sounds across all five frequencies compared with the conventional stethoscope. The Starkey SLI-ST3 stethoscope was better at amplifying normal heartbeats than the Cardionics E-Scope II and Littman Classic S.E. II; however, it came last for amplifying normal heartbeats of ~85 Hz. Cardionics E-Scope II had advantages in amplifying abnormal heartbeats (i.e., aortic valvular stenosis and pulmonic valvular stenosis) over the other two stethoscopes.

Conclusion: This study showed that amplified stethoscopes provided better amplification of normal and abnormal heart sounds across the five measured frequencies. Therefore, health professionals should interpret manufacturer claims regarding gain (dB) and frequency (Hz) with caution, and those with hearing loss should carefully investigate the "audio performance" of the stethoscopes. Future research should focus on these effects through coupling with hearing aids.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7305673PMC
http://dx.doi.org/10.4103/sjmms.sjmms_118_19DOI Listing

Publication Analysis

Top Keywords

heart sounds
20
amplified stethoscopes
16
frequency responses
12
conventional amplified
12
normal abnormal
12
abnormal heart
12
cardionics e-scope
12
valvular stenosis
12
responses conventional
8
acoustic analyses
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!