Objective: Low-dose CT is now widely used in the screening of lung cancer and the detection of pulmonary nodules. There has also been increasing interest in using Low-dose CT for evaluating emphysema. In conventional dose CT, the threshold of -950HU is a common threshold for density-based emphysema quantification for worldwide population. However, the optimal threshold for assessing emphysema at low-dose CT has not been determined. The purpose of this study is to determine the optimal threshold for low-dose CT quantification of emphysema for Chinese population.

Materials And Methods: In this study, 548 low-dose chest CT examinations acquired from different subjects (119 none, 49 mild, 163 moderate, 152 severe, and 65 very severe obstruction) are collected. At the level of the entire lung and individual lobes, the extent of emphysema was quantified by the percentage of the low attenuation area (LAA%) at a wide range of thresholds from -850HU to -1000HU. Both Pearson and Spearman's rank correlation coefficients were used to assess the correlations between 1) LAA% and pulmonary functions and 2) LAA% and the five-category classification. The statistical significance of the difference between correlation coefficients were evaluated using Steiger'Z test.

Results: LAA% had a good correlation with both pulmonary function (|r| = 0.1-0.600, p < 0.001) and the five-category classification (r = 0.163-0.602, p < 0.001) in both the entire lung and individual lobes under different thresholds. The highest correlation coefficient is obtained at -940HU instead of -950HU.

Conclusion: Low-dose CT can be used for quantitative assessment of emphysema, and the threshold of -940HU is a suitable threshold for quantifying emphysema in low-dose CT images for Chinese population.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2020.109094DOI Listing

Publication Analysis

Top Keywords

optimal threshold
12
threshold low-dose
8
low-dose quantification
8
quantification emphysema
8
correlation coefficients
8
low-dose
6
emphysema
6
emphysema objective
4
objective low-dose
4
low-dose screening
4

Similar Publications

The Diagnostic Utility of TRBC1 Immunohistochemistry in Mature T-Cell Lymphomas.

Mod Pathol

January 2025

Hematopathology Service, Department of Pathology and Laboratory Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA. Electronic address:

T-cell clonality assessment constitutes an essential part of the diagnostic evaluation of suspected T-cell neoplasms. Recent advances in flow cytometry-based analysis of TCR β chain constant region 1 (TRBC1) have introduced an accurate method of assessment of T-cell clonality. Its broader applicability is constrained due to the requirement of viable cells.

View Article and Find Full Text PDF

Superconducting quantum computing optimization based on multi-objective deep reinforcement learning.

Sci Rep

January 2025

School of Physics, Xi'an Jiaotong University, No.28 Xianning West Road, Xi'an, 710049, Shaanxi, P. R. China.

Deep reinforcement learning is considered an effective technology in quantum optimization and can provide strategies for optimal control of complex quantum systems. More precise measurements require simulation control at multiple experimental stages. Based on this, we improved a multi-objective deep reinforcement learning method in mathematical convex optimization theory for multi-process quantum optimal control optimization.

View Article and Find Full Text PDF

The built environment is an important determinant of travel demand and mode choice. Studying the relationship between the built environment and transportation usage can support and assist traffic policy interventions. Previous studies often assumed that this relationship is linear; however, the impact of the built environment on non-motorized travel efficiency may be more complex than the typically modeled linear relationships.

View Article and Find Full Text PDF

Risk assessment of persistent incidental pulmonary subsolid nodules to guide appropriate surveillance interval and endpoints.

Pulmonology

December 2025

Department of Diagnostic Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Guidelines for the follow-up of pulmonary subsolid nodule (SSN) vary in terms of frequency and criteria for discontinuation. We aimed to evaluate the growth risk of SSNs and define appropriate follow-up intervals and endpoints. The immediate risk (IR) and cumulative risk (CR) of SSN growth were assessed using the Kaplan-Meier method according to nodule consistency and size.

View Article and Find Full Text PDF

Introduction: Metabolic and bariatric surgery (MBS) is increasingly used for obesity and metabolic disease, with safety profiles showing it is among the safest major operations. The last 20 + years have noted significantly improved safety that has been accompanied by decreasing length of stay and select populations electing for outpatient surgery, leading to continued decreases in cost. Regardless, readmissions and complications still occur, requiring inpatient postoperative care (IP-POC).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!