Purpose: Reirradiation in the scalp area can be challenging given the proximity to organs at risk (OARs), such as the eye and brain. Our aim is to evaluate the dosimetric differences of volumetric modulated arc therapy (VMAT) and electron beam therapy (EBT) compared with 3-dimensional proton beam therapy (PBT).

Patients And Methods: We evaluated a patient with recurrent angiosarcoma of the left temporal scalp after prior surgical resections and radiation therapy to 60 Gy in 30 fractions who needed reirradiation. We generated VMAT, EBT, and PBT plans using the Pinnacle Treatment Planning System (TPS). Both VMAT and EBT plans used a skin bolus, whereas no bolus was used for the proton plan. Doses to the OARs, including cochlea, eyes, lens, lacrimal glands, optic nerves, optic chiasm, pituitary gland, and underlying brain, were compared.

Results: The reirradiation treatment dose was 60 Gy(RBE). Target volume coverage was comparable in all plans. Compared with VMAT and EBT, the PBT plan showed reductions in mean and maximum doses to all OARs. Without the use of protons, several OARs would have exceeded dose tolerance utilizing VMAT or electrons. Dose reduction of up to 100% was achieved for central and contralateral OARs.

Conclusion: Compared with VMAT and EBT, PBT resulted in dose reductions to all OARs, while maintaining excellent target coverage. PBT showed a significant advantage in treating superficially located skin cancers, such as angiosarcoma, without the need for a bolus. PBT can be considered in the upfront treatment and certainly in the reirradiation setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7038915PMC
http://dx.doi.org/10.14338/IJPT-19-00074DOI Listing

Publication Analysis

Top Keywords

vmat ebt
20
ebt pbt
12
beam therapy
8
doses oars
8
compared vmat
8
vmat
7
pbt
6
ebt
6
reirradiation
5
oars
5

Similar Publications

Background: EBT-XD film specially designed for high dose verifications such as stereotactic treatments. The dose response of the film can be affected by several factors, the curly nature of the film being one of them. In this study this curly nature of the film was investigated for stereotactic body radiotherapy (SBRT) plan verifications.

View Article and Find Full Text PDF

Aim: This study comprehensively investigated pre-treatment quality assurance (QA) for 100 cancer patients undergoing stereotactic treatments (SRS/SRT) using various detectors.

Methods: The study conducted QA for SRS/SRT treatments planned with a 6MV SRS beam at a dose rate of 1,000 MU/min, utilizing Eclipse v13.6 Treatment Planning System (TPS).

View Article and Find Full Text PDF

Modern radiotherapy techniques have advanced and become more sophisticated. End-to-end 3D verification of the complex radiotherapy dose distribution in an anthropomorphic phantom can ensure the accuracy of the treatment delivery. The phantoms commonly used for dosimetry are homogeneous solid water phantom which lacks the capability to measure the 3D dose distribution for heterogeneous tissues necessary for advanced radiotherapy techniques.

View Article and Find Full Text PDF

Purpose: Single-isocenter multi-target intracranial stereotactic radiotherapy (SIMT) is an effective treatment for brain metastases with complex treatment plans and delivery optimization necessitating rigorous quality assurance. This work aims to assess five methods for quality assurance of SIMT treatment plans in terms of their suitability and sensitivity to delivery errors.

Methods: Sun Nuclear ArcCHECK and SRS MapCHECK, GafChromic EBT Radiochromic Film, machine log files, and Varian Portal Dosimetry were all used to measure 15 variations of a single SIMT plan.

View Article and Find Full Text PDF

Evaluation of commercial devices for patient specific QA of stereotactic radiotherapy plans.

J Appl Clin Med Phys

August 2023

Department of Radiation Oncology, Medical College of Georgia, Augusta University, Augusta, Georgia, USA.

Stereotactic radiotherapy (SRT) methods have become common for the treatment of small tumors in various parts of the body. Small field dosimetry has a unique set of challenges when it comes to the pre-treatment validation of a radiotherapy plan that involves film dosimetry or high-resolution detectors. Comparison of commercial quality assurance (QA) devices to the film dosimetry method for pre-treatment evaluation of stereotactic radiosurgery (SRS), fractionated SRT, and stereotactic body radiation therapy treatment plans have been evaluated in this study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!