Gratings and holograms use patterned surfaces to tailor optical signals by diffraction. Despite their long history, variants with remarkable functionalities continue to be developed. Further advances could exploit Fourier optics, which specifies the surface pattern that generates a desired diffracted output through its Fourier transform. To shape the optical wavefront, the ideal surface profile should contain a precise sum of sinusoidal waves, each with a well defined amplitude, spatial frequency and phase. However, because fabrication techniques typically yield profiles with at most a few depth levels, complex 'wavy' surfaces cannot be obtained, limiting the straightforward mathematical design and implementation of sophisticated diffractive optics. Here we present a simple yet powerful approach to eliminate this design-fabrication mismatch by demonstrating optical surfaces that contain an arbitrary number of specified sinusoids. We combine thermal scanning-probe lithography and templating to create periodic and aperiodic surface patterns with continuous depth control and sub-wavelength spatial resolution. Multicomponent linear gratings allow precise manipulation of electromagnetic signals through Fourier-spectrum engineering. Consequently, we overcome a previous limitation in photonics by creating an ultrathin grating that simultaneously couples red, green and blue light at the same angle of incidence. More broadly, we analytically design and accurately replicate intricate two-dimensional moiré patterns, quasicrystals and holograms, demonstrating a variety of previously unattainable diffractive surfaces. This approach may find application in optical devices (biosensors, lasers, metasurfaces and modulators) and emerging areas in photonics (topological structures, transformation optics and valleytronics).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7116695 | PMC |
http://dx.doi.org/10.1038/s41586-020-2390-x | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Department of Microsystems Engineering (IMTEK), Laboratory for Chemistry & Physics of Interfaces (CPI), Albert Ludwigs Universität Freiburg, Georges Köhler Allee 103, 79110 Freiburg, Germany.
Glaucoma, a leading cause of blindness, demands innovative and effective treatments that surpass the limitations of current drug and surgical interventions to lower intraocular pressure. This study describes the generation of cell-repellent hydrogel patches, their deposition on the ocular surface, and a photoinduced chemical binding between the patches and the collagens of the eye. The hydrophilic and protein-repellent hydrogel patch is composed of a copolymer made from dimethylacrylamide and a comonomer unit with anthraquinone moieties.
View Article and Find Full Text PDFJ Med Internet Res
January 2025
I3A, LoUISE Research Group, University of Castilla-La Mancha, Albacete, Spain.
Background: Laparoscopic surgery training is a demanding process requiring technical and nontechnical skills. Surgical training has evolved from traditional approaches to the use of immersive digital technologies such as virtual, augmented, and mixed reality. These technologies are now integral to laparoscopic surgery training.
View Article and Find Full Text PDFJ Neuroophthalmol
January 2025
Sydney Eye Hospital and Save Sight Institute, University of Sydney, Sydney, NSW, Australia.
Eye Contact Lens
January 2025
Medical College of Wisconsin, Milwaukee, WI.
Purpose: To describe a rare case of infectious keratitis secondary to Brevundimonas diminuta, a gram-negative bacillus with fluoroquinolone resistance and rare clinical isolation.
Methods: A 50-year-old man with contact lens overuse presented with a large corneal ulcer and hand motion visual acuity. Initial treatment with fortified topical tobramycin and vancomycin yielded slow improvement, and initial culture grew Staphylococcus epidermidis, Staphylococcus hominis, and Corynebacterium bovis.
Health Phys
January 2025
Department of Radiation Oncology & Medical Physics, Inova Health Systems, Fairfax, Virginia.
Occupational radiation dosimeters that return high readings cannot always be explained by circumstances in the workplace. For this experiment, a series of optically stimulated luminescence (OSL) dosimeters were brought to airports to estimate the radiation dose OSLs would receive should a worker accidentally bring their dosimeter with them during travel. The OSLs returned readings between 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!