To compare and contrast the midterm outcomes of the E-liac and Zenith (ZBIS) iliac branch devices (IBDs) for the preservation of the internal iliac artery (IIA) in aneurysms involving the iliac bifurcation. Between January 2014 and December 2018, 84 consecutive patients (median age 74 years; 76 men) were electively treated with the E-liac (n=44) or ZBIS (n=40) IBDs and were retrospectively analyzed to evaluate the technical success, patency, need for reintervention, and mortality associated with these devices. Technical success was achieved in 95 of 99 implantations (95.9%) without any statistically significant difference between the groups (93.7% vs 98.0%, p=0.114). During the first 30 days, 3 occlusions in the ZBIS group and 1 in the E-liac group were identified. There was 1 perioperative death in the ZBIS group. The median follow-up was 37 months for the ZBIS group and 28 months for the E-liac group (p=0.657). Six patients from the ZBIS group and 7 from the E-liac group were lost to follow-up. Among the remaining, there were 2 further deaths recorded, 1 in each group. Four further reinterventions in the E-liac group and 2 in the ZBIS group were performed during follow-up. The Kaplan-Meier estimates of freedom from reintervention were 87.2% (95% CI 82.6% to 90.2%) for the ZBIS group and at 86.0% (95% CI 83.7% to 89.1%) for the E-liac group (p=0.563); the freedom from occlusion estimates were 89.7% (95% CI 85.8% to 94.5%) and 95.3% (95% CI 92% to 98.7%; p=0.317), respectively. The E-liac and the ZBIS IBDs showed equally high technical success, midterm patency, and low reintervention rates.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/1526602820934762 | DOI Listing |
Diagnostics (Basel)
January 2023
Multi-Modality Medical Imaging (M3i) Group, Faculty of Science and Technology, Technical Medical Centre, University of Twente, 7522 NB Enschede, The Netherlands.
To what extent the stentgraft design of iliac branch devices (IBDs) relates to dynamic deformation is currently unknown. Therefore, this study aimed to quantify and compare displacement and geometry changes during the cardiac cycle of two common IBDs. This paper presents a two-center trial with patients treated with a Zenith bifurcated iliac side (ZBIS) or Gore iliac branch endoprosthesis (IBE).
View Article and Find Full Text PDFOccup Ther Health Care
April 2023
Occupational Therapy Department, Creighton University, Omaha, NE, USA.
The purpose of this cross-sectional survey was to examine the quality of life and level of burden experienced by mothers of children and adolescents with type 1 diabetes (n = 199). Data was collected using a sociodemographic questionnaire, the Zarit Burden Interview Scale (ZBIS), and the World Health Organization Quality of Life-BREF (WHOQOL-BREF) instruments. A simple descriptive analysis was conducted, and the Pearson's correlation coefficient was utilized to determine the correlation among variables.
View Article and Find Full Text PDFAnn Vasc Surg
April 2021
Vascular Surgery Unit, S. Maria della Misericordia Hospital, University of Perugia, Perugia, Italy.
Background: Current guidelines indicate iliac-branched endografts (IBDs) as the ideal means to preserve pelvic perfusion during endovascular aortic repair. Because patient vascular anatomy represents the main limitation to extensive use of these devices, off-label application may be considered to expand the number of patients being treated. The aim of this study is to evaluate long-term outcomes obtained using the Cook ZBIS endograft in the treatment of aortoiliac aneurysms as per or outside manufacturer's instruction for use (IFU).
View Article and Find Full Text PDFJ Endovasc Ther
October 2020
Department of Vascular and Endovascular Surgery, University of Cologne, Germany.
To compare and contrast the midterm outcomes of the E-liac and Zenith (ZBIS) iliac branch devices (IBDs) for the preservation of the internal iliac artery (IIA) in aneurysms involving the iliac bifurcation. Between January 2014 and December 2018, 84 consecutive patients (median age 74 years; 76 men) were electively treated with the E-liac (n=44) or ZBIS (n=40) IBDs and were retrospectively analyzed to evaluate the technical success, patency, need for reintervention, and mortality associated with these devices. Technical success was achieved in 95 of 99 implantations (95.
View Article and Find Full Text PDFJ Vasc Surg
April 2020
Department of Vascular Surgery, University of Florence, Florence, Italy.
Objective: The objective of this study was to compare the perioperative and midterm results of Zenith Bifurcated Iliac Side (ZBIS; Cook Medical, Bloomington, Ind) and Gore Iliac Branch Endoprosthesis (IBE; W. L. Gore & Associates, Flagstaff, Ariz) iliac branch devices (IBDs) in treatment of dilated iliac bifurcations in patients with similar anatomic and clinical preoperative features.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!