Background: Noninvasive ventilation may relieve dyspnea in advanced diseases, but noninvasive ventilation through mouthpiece has not been tested in palliative care.

Aim: To assess the feasibility of mouthpiece ventilation in relieving dyspnea among patients with advanced disease.

Design: In this prospective single-arm pilot study, the change in dyspnea by mouthpiece ventilation was measured with numeric rating scale (0-10) and 100-mm visual analogue scale. Overall, benefit and adverse events of the therapy were also assessed.

Setting/participants: Twenty-two patients with an advanced disease and dyspnea from the Tampere University Hospital or Pirkanmaa Hospice were treated with mouthpiece ventilation. The patients used mouthpiece ventilation as long as they preferred, but for a minimum of 5 min.

Results: After the treatment period lasting a median of 13.5 min, mean decrease in dyspnea was -1.1 (95 % confidence interval = -2.2 to -0.1,  = 0.034) on numeric rating scale and -11.8 mm (95 % confidence interval = -19.9 to -3.7,  = 0.006) on visual analogue scale. Nonetheless, there was a high variability in this effect between individual patients. About half of the patients found mouthpiece ventilation beneficial. No serious adverse events occurred, but dry mouth was the most common adverse event. Anxiety did not increase with mouthpiece ventilation.

Conclusion: Mouthpiece ventilation is feasible and may relieve dyspnea in some patients with an advanced disease. Further studies are needed, and these might concentrate on stable patients in early palliative care. Before initiation, this study was registered at clinicaltrials.gov (study no. NCT03012737).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7495670PMC
http://dx.doi.org/10.1177/0269216320935003DOI Listing

Publication Analysis

Top Keywords

mouthpiece ventilation
28
patients advanced
12
mouthpiece
9
single-arm pilot
8
pilot study
8
ventilation
8
noninvasive ventilation
8
relieve dyspnea
8
dyspnea patients
8
numeric rating
8

Similar Publications

Objective: Abdominoplasty may generate an increase in the intra-abdominal pressure (IAP) and consequently an alteration in the pulmonary ventilation. The purpose of this study was to evaluate the potential alterations in the maximal static inspiratory pressure (MIP) and maximal static expiratory pressure (MEP) after abdominoplasty.

Methods: Thirty-three female patients, aged between 18 and 60, with type III/B Nahas abdominal deformity that underwent abdominoplasty with plication of the anterior rectus and external oblique aponeurosis were selected.

View Article and Find Full Text PDF
Article Synopsis
  • The methacholine challenge test (MCT) is a key method for assessing airway hyperresponsiveness, particularly for diagnosing and treating bronchial asthma.
  • A consensus group of experts in respiratory health has updated guidelines on MCT usage, focusing on common clinical issues, preparation, safety, and result interpretation.
  • The updated guidelines specify who should undergo the MCT, outline absolute contraindications, and aim to assist healthcare practitioners in effectively using the test for patient assessment and treatment decisions.
View Article and Find Full Text PDF

Lack of effect of an in-line filter on cardiopulmonary exercise testing variables in healthy subjects.

Eur J Appl Physiol

March 2024

Division of Respiratory and Critical Care Physiology and Medicine, Department of Medicine, The Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center, 1124 W Carson St, CDCRC Building, Torrance, CA, 90502, USA.

Purpose: Pathogen transmission during cardio-pulmonary exercise testing (CPET) is caused by carrier aerosols generated during respiration.

Methods: Ten healthy volunteers (age range: 34 ± 15; 4 females) were recruited to see if the physiological reactions to ramp-incremental CPET on a cycle ergometer were affected using an in-line filter placed between the mouthpiece and the flow sensor. The tests were in random order with or without an in-line bacterial/viral spirometer filter.

View Article and Find Full Text PDF

Background: Extubation failure, defined as reintubation within 48 h, is associated with increased intensive care unit (ICU) length of stay and higher mortality risk. One cause of extubation failure is secretion retention, resulting from an inability to cough effectively. Mechanical insufflation-exsufflation (MI-E) simulates a cough aiding secretion clearance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!