ELISA has become a standard analytical tool in the numerous branches of science and industry. Processing of the ELISA results may be a multistep process, often requiring a prior adaptation, using proprietary software, or exporting the results into external internet platforms. It may be problematic in the light of good documentation practices and maintaining good data integrity. In this paper, we present the development and application of the ELISA Tool software. The program is based on a Python scripting programming language and is available under an open-source license. The ELISA Tool allows users to fully control and validate the calculation procedure through a user-friendly graphical user interface. The modular architecture of the software allows its application in other information technology (IT) projects used for data processing in research laboratories. We successfully applied the ELISA Tool for the analysis of real-life samples. The ELISA Tool allowed import of the measurement data, an approximation of the calibration curves with two different algorithms, exploration and diagnostics of the model fit, and generation of the final report with the calculations while maintaining the raw data file unchanged. We report here for the first time the implementation of the idea of full control over data processing, from measured raw data to the final report. We obtained a transparent, open, registered system of data processing control, independent of third parties. The modular and flexible architecture of the created software encourages its further development following the individual demands of the users.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2020.113415DOI Listing

Publication Analysis

Top Keywords

elisa tool
16
data processing
12
final report
8
raw data
8
elisa
7
data
7
tool
6
novel open
4
open source
4
source tool
4

Similar Publications

Different agencies have emphasized the need to evaluate current serological methods for screening patients with suspected urogenital schistosomiasis. However, there is still a lack of evidence regarding the most appropriate methods for this purpose. Here we assessed the diagnostic efficacy of a newly developed serological technique that utilizes the recombinant protein -TSP-2, applied to the urine and serum of migrants suspected of having urogenital schistosomiasis.

View Article and Find Full Text PDF

Introduction: Differential diagnosis of rare idiopathic inflammatory myopathies (IIM) is mainly based on clinical aspects, muscle biopsy analysis, and auxiliary assays that determine myositis-specific and associated autoantibodies (MSA and MAA). While MSAs are considered specific for their respective IIM subclass, MAAs can be present in more than one subclass and in other conditions. This study compares results of a multispecific line blot assay with the final diagnosis of IIM patients based on clinical features and muscle biopsy to draw conclusions for the test's applicability in the diagnostic workflow.

View Article and Find Full Text PDF

A wearable antifouling electrochemical sensor integrated with an antimicrobial microneedle array for uric acid detection in interstitial fluid.

Anal Chim Acta

February 2025

Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science & Technology, Qingdao, 266042, China. Electronic address:

Wearable microneedle array (MNA) based electrochemical sensors have gained increasing attention for their capability to analyze biomarkers in the interstitial fluid (ISF), enabling noninvasive, continuous monitoring of health parameters. However, challenges such as nonspecific adsorption of biomolecules on the sensor surfaces and the risk of infection at the microneedle penetration sites hinder their practical application. Herein, a wearable dual-layer microneedle patch was prepared to overcome these issues by integrating an antimicrobial microneedle layer with an antifouling sensing layer.

View Article and Find Full Text PDF

Objective: Colorectal cancer (CRC) is the second leading cause of cancer-related deaths worldwide. Engineered biomolecules can be used as a targeted tool to deliver drugs directly to tumors that reduce the adverse effects of conventional treatments. We aimed to prepare non-targeted oxaliplatin-loaded chitosan nanoparticles (OXPT-CS NPs) and targeted OXPT-CS NPs decorated with cetuximab single-chain variable fragment (scFv) to send both NPs to epidermal growth factor receptor (EGFR) overexpressing HCT 116 cells, a human colorectal carcinoma cell line, for comparing their cytotoxicity.

View Article and Find Full Text PDF

Validation of an in house iELISA for serodiagnosis of caprine brucellosis and evaluation of the performance of a B. neotomae lysate for the detection of anti-smooth Brucella specific antibodies in ruminants.

Vet Microbiol

January 2025

Instituto de Patobiología - Instituto de Patobiología Veterinaria (IP-IPVET), UEDD INTA-Conicet, Nicolás Repetto y de Los Reseros s/n (B1686), Hurlingham, Buenos Aires, Argentina; CONICET, Godoy Cruz 2290 (C1425FQB), CABA, Argentina. Electronic address:

Enzyme-linked immunosorbent assay (ELISA) is a widely used and effective tool for detection of anti-Brucella antibodies in serum, easy to perform with high sensitivity and specificity. In this study, we validated an in-house indirect ELISA using B. melitensis whole cell lysate as antigen (Bm-WCL iELISA) for the serodiagnosis of caprine brucellosis and evaluated the use of BSL-2 B.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!