Purpose: The introduction of advanced treatment techniques in proton therapy, such as intensity-modulated proton therapy, leads to an increased need for patient-specific quality assurance, especially an accurate treatment plan verification becomes inevitable. In this study, signal theoretical analysis of dose distributions in scanned proton therapy is performed to investigate the feasibility and limits of two-dimensional (2D) detector arrays for treatment plan verification.
Methods: 2D detector arrays are characterized by two main aspects: the distance between the single detectors on the array or the sampling frequency; and the lateral response functions of a single detector. The analysis is based on single spots, reference fields and on measured and calculated dose distributions of typical intensity-modulated proton therapy treatment plans with and without range shifter. Measurements were performed with Gafchromic EBT3 films (Ashland Speciality Ingredients G.P., Bridgewater, NJ, USA), the MatriXX PT detector array (IBA Dosimetry, Schwarzenbruck, Germany) and the OCTAVIUS detector array 1500XDR (PTW-Freiburg, Germany) at an IBA Proteus PLUS proton therapy system (Ion Beam Applications, Louvain-la-Neuve, Belgium). Dose calculations were performed with the treatment planning system RayStation 6 or 8 (RaySearch Laboratories, Sweden).
Results: The Fourier analysis of the data of the treatment planning system and film measurements show maximum frequencies of 0.06/mm for the plan with range shifter and 0.083/mm for the plan without range shifter. According to the Nyquist theorem, this corresponds to minimum required sampling distances of 8.3 and 6 mm, respectively. By comparison, the sampling distances of the arrays of 7.6 mm (MatriXX PT) and 7.1 mm (OD1500XDR) are sufficient to reconstruct the dose distributions adequately from measurements if range shifters are used, whereas some fields of the plans without range shifter violated the Nyquist requirement. The lateral dose response functions of the single detectors within the arrays have clearly higher frequencies than the treatment plans and thus the volume effect only slightly influences the measurements. Consequently, the array measurements show high gamma passing rates with at least 96 % and a good agreement between the investigated line profiles.
Conclusion: The results indicate that the detector dimensions and sampling distances of the arrays are in most studied cases adequate not to substantially influence the measurement process when they are used for analyzing typical intensity-modulated proton therapy treatment plans. Nevertheless, clinical conditions have been identified, for instance treatment plans without range shifter, under which the Nyquist theorem is violated such that a full representation of the dose distributions with the measurements is not feasible. In these cases, analysis of measurements is limited to pointwise comparisons.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/mp.14346 | DOI Listing |
J Clin Med Res
January 2025
Department of Clinical Sciences, Malmo, Lund University, Malmo, Sweden.
Background: Upper gastrointestinal bleeding (UGIB) is a common and potentially fatal medical emergency. This study aimed to investigate the frequency, causes, outcomes, and efficacy of endoscopy in the treatment of UGIB at King Fahad Central Hospital in Jazan, Saudi Arabia.
Methods: Between January 2017 and December 2023, a retrospective study was performed including all hospitalized patients with UGIB.
Adv Radiat Oncol
February 2025
Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas.
Purpose: Treatment options for leptomeningeal metastasis (LM) are limited. A recent phase 2 study found that proton craniospinal irradiation (pCSI) was well-tolerated and improved survival. We report our experience with pCSI for solid-tumor LM.
View Article and Find Full Text PDFPhys Imaging Radiat Oncol
January 2025
Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.
Cancer Cell Int
January 2025
Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy.
Background: Mounting evidence underline the relevance of macromolecular complexes in cancer. Integrins frequently recruit ion channels and transporters within complexes which behave as signaling hubs. A complex composed by β1 integrin, hERG1 K channel, the neonatal form of the Na channel Na 1.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
January 2025
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, Texas, USA. Electronic address:
Purpose: Proton FLASH has been investigated using cyclotron and synchrocyclotron beamlines but not synchrotron beamlines. We evaluated the impact of dose rate (ultra-high [UHDR] vs. conventional [CONV]) and beam configuration (shoot-through [ST] vs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!