COVID-19 Ag Respi-Strip, an immunochromatographic (ICT) assay for the rapid detection of SARS-CoV-2 antigen on nasopharyngeal specimen, has been developed to identify positive COVID-19 patients allowing prompt clinical and quarantine decisions. In this original research article, we describe the conception, the analytical and clinical performances as well as the risk management of implementing the COVID-19 Ag Respi-Strip in a diagnostic decision algorithm. Development of the COVID-19 Ag Respi-Strip resulted in a ready-to-use ICT assay based on a membrane technology with colloidal gold nanoparticles using monoclonal antibodies directed against the SARS-CoV and SARS-CoV-2 highly conserved nucleoprotein antigen. Four hundred observations were recorded for the analytical performance study and thirty tests were analyzed for the cross-reactivity study. The clinical performance study was performed in a retrospective multi-centric evaluation on aliquots of 328 nasopharyngeal samples. COVID-19 Ag Respi-Strip results were compared with qRT-PCR as golden standard for COVID-19 diagnostics. In the analytical performance study, the reproducibility showed a between-observer disagreement of 1.7%, a robustness of 98%, an overall satisfying user friendliness and no cross-reactivity with other virus-infected nasopharyngeal samples. In the clinical performance study performed in three different clinical laboratories during the ascendant phase of the epidemiological curve, we found an overall sensitivity and specificity of 57.6 and 99.5%, respectively with an accuracy of 82.6%. The cut-off of the ICT was found at CT <22. User-friendliness analysis and risk management assessment through Ishikawa diagram demonstrate that COVID-19 Ag Respi-Strip may be implemented in clinical laboratories according to biosafety recommendations. The COVID-19 Ag Respi-Strip represents a promising rapid SARS-CoV-2 antigen assay for the first-line diagnosis of COVID-19 in 15 min at the peak of the pandemic. Its role in the proposed diagnostic algorithm is complementary to the currently-used molecular techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7227790 | PMC |
http://dx.doi.org/10.3389/fmed.2020.00225 | DOI Listing |
Objective: The objective of this study was to evaluate the performance of seven antigen rapid diagnostic tests (Ag RDTs) in a clinical setting to identify those that could be recommended for use in the diagnosis of SARS-CoV-2 infection in Uganda.
Methods: This was a cross-sectional prospective study. Nasopharyngeal swabs were collected consecutively from COVID-19 PCR positive and COVID-19 PCR negative participants at isolation centers and points of entry, and tested with the SARS-CoV-2 Ag RDTs.
J Virol Methods
February 2022
Service de Microbiologie clinique, Groupe hospitalier Paris Saint Joseph, Paris, France; Institut Micalis UMR 1319, Université Paris-Saclay, INRAe, AgroParisTech, Châtenay Malabry, France.
This communication described how the Coris BioConcept COVID-19 Ag Respi-Strip test (Coris-Ag) was implemented in the workflow of our clinical microbiology laboratory for COVID-19 diagnosis. The diagnostic performance statistics (sensitivity, specificity) of the Coris-Ag were evaluated against a gold standard, the RealStar SARS-CoV-2 RT-PCR kit 1.0.
View Article and Find Full Text PDFJ Clin Med
June 2021
Department of Clinical Microbiology, Center for Interdisciplinary Research on Medicines (CIRM), University of Liège, 4000 Liège, Belgium.
(1) Background: In the current context of the COVID-19 crisis, there is a need for fast, easy-to-use, and sensitive diagnostic tools in addition to molecular methods. We have therefore decided to evaluate the performance of newly available antigen detection kits in "real-life" laboratory conditions. (2) Methods: The sensitivity and specificity of two rapid diagnostic tests (RDT)-the COVID-19 Ag Respi-Strip from Coris Bioconcept, Belgium (CoRDT), and the coronavirus antigen rapid test cassette from Healgen Scientific, LLC, USA (HeRDT)-were evaluated on 193 nasopharyngeal samples using RT-PCR as the gold standard.
View Article and Find Full Text PDFLancet Microbe
July 2021
Institute of Virology, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany; German Centre for Infection Research, Berlin, Germany. Electronic address:
Background: Antigen point-of-care tests (AgPOCTs) can accelerate SARS-CoV-2 testing. As some AgPOCTs have become available, interest is growing in their utility and performance. Here we aimed to compare the analytical sensitivity and specificity of seven commercially available AgPOCT devices.
View Article and Find Full Text PDFJ Med Virol
May 2021
Pathogenesis and Control of Chronic Infections, INSERM, Etablissement Français du Sang, CHU Montpellier, Université de Montpellier, Montpellier, France.
The implementation of rapid diagnostic tests (RDTs) may enhance the efficiency of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing, as RDTs are widely accessible and easy to use. The aim of this study was to evaluate the performance of a diagnosis strategy based on a combination of antigen and immunoglobulin M (IgM) or immunoglobulin G (IgG) serological RDTs. Plasma and nasopharyngeal samples were collected between 14 March and 11 April 2020 at hospital admission from 45 patients with reverse transcription polymerase chain reaction (RT-PCR) confirmed COVID-19 and 20 negative controls.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!