Structural biocompatibility is a fundamental requirement for chronically stable bioelectronic devices. Newest neurotechnologies are increasingly focused on minimizing the foreign body response through the development of devices that match the mechanical properties of the implanted tissue and mimic its surface composition, often compromising on their robustness. In this study, an analytical approach is proposed to determine the threshold of conformability for polyimide-based electrocorticography devices. A finite element model was used to quantify the depression of the cortex following the application of devices mechanically above or below conformability threshold. Findings were validated in vivo on rat animal models. Impedance measurements were performed for 40 days after implantation to monitor the status of the biotic/abiotic interface with both conformable and non-conformable implants. Multi-unit activity was then recorded for 12 weeks after implantation using the most compliant device type. It can therefore be concluded that conformability is an essential prerequisite for steady and reliable implants which does not only depend on the Young's modulus of the device material: it strongly relies on the relation between tissue curvature at the implantation site and corresponding device's thickness and geometry, which eventually define the moment of inertia and the interactions at the material-tissue interface.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.biomaterials.2020.120178 | DOI Listing |
Microsyst Nanoeng
May 2023
Institute of Microelectronics, University of Ulm, D-89081 Ulm, Germany.
Demands for neural interfaces around functionality, high spatial resolution, and longevity have recently increased. These requirements can be met with sophisticated silicon-based integrated circuits. Embedding miniaturized dice in flexible polymer substrates significantly improves their adaptation to the mechanical environment in the body, thus improving the systems' structural biocompatibility and ability to cover larger areas of the brain.
View Article and Find Full Text PDFSci Rep
April 2023
Biomedical Engineering, University of Michigan, Ann Arbor, 48105, USA.
Shape-morphable electrode arrays can form 3D surfaces to conform to complex neural anatomy and provide consistent positioning needed for next-generation neural interfaces. Retinal prostheses need a curved interface to match the spherical eye and a coverage of several cm to restore peripheral vision. We fabricated a full-field array that can (1) cover a visual field of 57° based on electrode position and of 113° based on the substrate size; (2) fold to form a compact shape for implantation; (3) self-deploy into a curvature fitting the eye after implantation.
View Article and Find Full Text PDFMicromachines (Basel)
October 2022
NeuroOne Medical Technologies Corporation, Eden Prairie, MN 55344, USA.
Subdural electrode arrays are used for monitoring cortical activity and functional brain mapping in patients with seizures. Until recently, the only commercially available arrays were silicone-based, whose thickness and lack of conformability could impact their performance. We designed, characterized, manufactured, and obtained FDA clearance for 29-day clinical use (510(k) K192764) of a new thin-film polyimide-based electrode array.
View Article and Find Full Text PDFBiomaterials
October 2020
Department of Microsystems Engineering (IMTEK), University of Freiburg, Germany; BrainLinks-BrainTools Center, University of Freiburg, Germany; Bernstein Center Freiburg, University of Freiburg, Germany.
Structural biocompatibility is a fundamental requirement for chronically stable bioelectronic devices. Newest neurotechnologies are increasingly focused on minimizing the foreign body response through the development of devices that match the mechanical properties of the implanted tissue and mimic its surface composition, often compromising on their robustness. In this study, an analytical approach is proposed to determine the threshold of conformability for polyimide-based electrocorticography devices.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2019
Only thin-film technology can satisfy the requirements of high spatial selectivity at high-channel-count electrode array designs by simultaneously good conformability to the targeted tissue through mechanical flexibility enriching future applications of functional neural stimulation. However, caused by the high impact of the microstructure on the mechanical and electrochemical film properties, varying fabrication processes of the same thin-film makes the difference between acute and chronic long-term stable electrodes. The influence of standard clinical electrical pulsing on flexible polyimide-based thin-film platinum electrodes for neuroprostheses, either sputter deposited or evaporated, and different diameters was assessed and compared.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!