Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The objective was to systematically review the published literature on the diagnostic accuracy of out-of-hospital respiratory measures for identifying patients with serious injury, focusing on measures feasible for field triage by emergency medical services personnel.
Methods: We searched Ovid MEDLINE, CINAHL, and the Cochrane databases from January 1, 1996, through August 31, 2017. We included studies on the diagnostic accuracy (sensitivity, specificity, and area under the receiver operating characteristic curve [AUROC]) for all respiratory measures used to identify patients with serious injury (resource use, serious anatomic injury, and mortality). We assessed studies for risk of bias and strength of evidence (SOE). We performed meta-analysis for measures with sufficient data.
Results: We identified 46 articles reporting results of 44 studies. Out-of-hospital respiratory measures included respiratory rate, pulse oximetry, and airway support. Meta-analysis was only possible for respiratory rate, which demonstrated a pooled sensitivity for serious injury of 13% (95% confidence interval [CI] = 5 to 29, I = 97.8%), specificity of 96% (95% CI = 83 to 99, I = 99.6%), and AUROC of 0.70 (95% CI = 0.66 to 0.79, I = 16.6%). For oxygen saturation, sensitivity ranged from 13% to 63%; specificity, 85% to 99%; and AUROC, 0.53 to 0.76. Need for airway support had a sensitivity of 8% to 53% and specificity of 61% to 100%; studies did not report AUROC. Across respiratory measures, the SOE was low. Other respiratory measures (pH, end-tidal carbon dioxide [CO ], and sublingual partial pressure of CO ) were reported only in emergency department studies.
Conclusions: Data on the accuracy of out-of-hospital respiratory measures for field triage are limited and of low quality. Based on available research, respiratory rate, oxygen saturation, and need for airway intervention all have low sensitivity, high specificity, and poor to fair discrimination for identifying seriously injured patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/acem.14055 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!