Background: Ultrasonography is an image technique that allows rheumatologists to visualize structural and inflammatory changes within a joint. The objective of this study was to assess the interobserver and intraobserver reliability of musculoskeletal ultrasound (US) in the detection of inflammatory and destructive joint changes in patients with polyarthritis.
Methods: A Delphi exercise was undertaken to standardize and adapt the EULAR-OMERACT elementary US definitions of inflammatory lesions (effusion, synovial hypertrophy, power Doppler, bone erosions, and synovitis) for each joint. Fifteen patients were analyzed, and video clips of 600 joints were collected. Each joint was scored for the presence of each elementary component, on 2 separate occasions, by 6 examiners. Interobserver and intraobserver agreement analysis was assessed through Fleiss κ coefficient (κ).
Results: Considering all patients and all joints, the interobserver values were highest for erosions and lowest for effusion (κ = 0.7314 and κ = 0.6044, respectively). When analyzing different regions, the highest interobserver agreement was for tibiotalar joint (κ = 0.8043) and the lowest for wrist (κ = 0.6767). Intraobserver reliability was excellent for each and all elementary components and anatomical region.
Conclusions: The present study showed either a good or excellent US interobserver and intraobserver reliability in elementary elements and anatomical region. This kind of US reliability exercises are important for standardization of exploration in everyday practice by reducing the variability associated with this imaging technique, and ensuring a greater degree of homogeneity and future comparability in the assessment of disease activity in polyarthritis patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RHU.0000000000001440 | DOI Listing |
Q J Nucl Med Mol Imaging
January 2025
Section of Nuclear Medicine and Diagnostic Imaging, International Atomic Energy Agency, Vienna, Austria.
Background: One can assess cortical defects on the early images of [99mTc]Tc-MAG3 renography. We aimed to assess interobserver and intraobserver reproducibility for detecting renal cortical defects using [99mTc]Tc-MAG3 for adults and children; identify causes for poor inter- and intraobserver reproducibility and to assess the effect of the kidney to background ratio (KTBR) on reproducibility.
Methods: One hundred adult and 200 pediatric renograms were included.
J Clin Med
January 2025
Derby Fertility Unit, Royal Derby Hospital, University Hospital of Derby and Burton, Derby DE22 3NE, UK.
: The aim of this study is to assess the inter- and intra-observer reproducibility of the identification of direct and indirect ultrasonographic features of adenomyosis as defined by the revised Morphological Uterus Sonographic Assessment (MUSA) consensus (2022). : A cohort of 74 women, aged 18 to 45, were recruited from the recurrent miscarriage and general gynaecology clinic at a university-based fertility centre. All the participants underwent 2D and 3D transvaginal Ultrasound scan (TVS) examination in the late follicular and early luteal phase.
View Article and Find Full Text PDFUltrasound Obstet Gynecol
January 2025
Robinson Research Institute, University of Adelaide, Adelaide, Australia.
Objectives: The development of valuable artificial intelligence (AI) tools to assist with ultrasound diagnosis depends on algorithms developed using high-quality data. This study aimed to test the intra- and interobserver agreement of a proposed image-quality scoring system to quantify the quality of gynecological transvaginal ultrasound (TVS) images, which could be used in clinical practice and AI tool development.
Methods: A proposed scoring system to quantify TVS image quality was created following a review of the literature.
J Cardiovasc Dev Dis
January 2025
Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, 37126 Verona, Italy.
We aimed to evaluate the accuracy and reproducibility of right ventricular output (RVO) using different anatomical landmarks: the internal pulmonary valve diameter (PVD) between the valve hinge points (hinge-PVD) according to the traditional technique, and PVD between the valve leaflet tips (tip-PVD). This was a retrospective analysis of prospective collected data. All neonates with echocardiographic measurements of RVO and left ventricular output (LVO) without congenital heart disease, including patent ductus arteriosus and patent foramen ovale > 3 mm, were included.
View Article and Find Full Text PDFJ Endovasc Ther
January 2025
Department of Vascular Surgery, Zuyderland Medical Centre, Heerlen, The Netherlands.
Objective: The gold standard imaging modality for assessing crural arterial disease is digital subtraction angiography (DSA). Using DSA, the operator can estimate the diameter and degree of stenosis and determine the diameter of the balloon. Since these measures are estimates, it allows for interobserver and intraobserver variability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!