The true extent of a tumor is difficult to visualize, during radiotherapy, using current modalities. In the present study, the safety and feasibility of a mixture of N-butyl cyanoacrylate and lipiodol (NBCA/Lip) was evaluated in order to investigate the optimal combination for application as a fiducial marker for radiotherapy. Four combinations of NBCA/Lip injection (1:1-0.1, 1:1-0.15, 1:3-0.1 and 1:3-0.15 ml) were injected into the subcutaneous tissue of BALB/c mice. The changes in gross histopathology, body weight, skin score, marker volume, neutrophil and macrophage counts were observed to analyze the effects of the different mixing ratios and injection volumes, in order to identify the best combination. Evaluation according to the International Organization for Standardization criteria was further conducted in order to test the biocompatibility of the mixture, including an acute systematic assay with mice, cytotoxicity with L929 fibroblasts and delayed-type hypersensitivity tests with guinea pigs and an intradermal test with rabbits. The results revealed that at the seventh week, 42 markers (42/48; 87.5%) were still visible using computed tomography (CT) imaging. No serious adverse effects were observed throughout the study period; however, the combination of 1:1-0.1 ml had the lowest body weight and worst skin score. A review of the histopathological reaction to NBCA/Lip revealed a combination of acute inflammation, chronic inflammation, granulation tissue, foreign-body reaction and fibrous capsule formation. The 1:1 NBCA combination ratio resulted in the most intense tissue repair reaction and a slower degradation rate of markers. In general, the combination of 1:3-0.15 ml had a better fusion with local tissue, maintained a stable imaging nodule on CT images for 7 weeks and the final biocompatibility test demonstrated its safety. Overall, the findings of the present study demonstrated NBCA/Lip as a safe and feasible fiducial marker, when using the 1:3-0.15 ml combination.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7286123 | PMC |
http://dx.doi.org/10.3892/ol.2020.11591 | DOI Listing |
J Clin Med
January 2025
Department of Cardiovascular Surgery, Houston Methodist Hospital, 6550 Fannin St, Houston, TX 77030, USA.
: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Department of Ophthalmology, University of Lübeck, University Medical Center Schleswig-Holstein, Campus Lübeck, 23562 Lübeck, Germany.
: Accurate target definition, treatment planning and delivery increases local tumor control for radiotherapy by minimizing collateral damage. To achieve this goal for uveal melanoma (UM), tantalum fiducial markers (TFMs) were previously introduced in proton and photon beam radiotherapy. However, TFMs cause pronounced scattering effects in imaging that make the delineation of small tumors difficult.
View Article and Find Full Text PDFJ Prosthodont
January 2025
Department of Prosthodontics, Jordan University of Science & Technology, Irbid, Jordan.
Purpose: To investigate the feasibility and accuracy (trueness and precision) of facial scanning and virtual patient representation (VPR).
Materials And Methods: One participant was recruited and informed consent was obtained. VPR was performed 30 times with a custom fabricated intraoral scan body (ISB).
Cancer Sci
January 2025
Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
To report clinical outcomes following highly hypofractionated biaxially rotational dynamic radiation therapy (BROAD-RT), a unique radiation therapy method that facilitates non-coplanar volumetric-modulated arc therapy (VMAT) without the need to rotate the couch or reposition the patient, for high-risk prostate cancer (PCa) with simultaneous integrated boost (SIB) for intra-prostatic dominant lesions (IPDLs), we performed a single-center prospective pilot study. In this study, patients with high-risk PCa according to the D'Amico classification or those with cT3aN0M0 PCa were eligible. VMAT was performed using BROAD-RT, and a dose of 54 Gy in 15 fractions was prescribed for the prostate in combination with SIB for IPDLs at a dose of 57 Gy in 15 fractions.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Oxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
Purpose: Solid crystalline spin probes, such as lithium phthalocyanine (LiPc) and lithium octa-n-butoxynaphthalocyanine (LiNc-BuO), allow repeated oxygen measurement using electron paramagnetic resonance (EPR). Due to their short relaxation times, their use for pulse EPR oxygen imaging is limited. In this study, we developed and tested a new class of solid composite spin probes that modified the relaxation rates R and R of LiPc or LiNc-BuO probes, which allowed pO measurements in the full dynamic (0-760 torr) range.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!