A finite element analysis of tibial tritanium cones without stems in varying bone defects.

Knee

School of Engineering, Institute for Bioengineering, The University of Edinburgh, Alrick Building, The King's Buildings, Edinburgh EH9 3BF, UK. Electronic address:

Published: June 2020

Background: In the UK around 10% of hip and knee arthroplasties are revision operations. At revision total knee arthroplasty (rTKA), bone loss management is critical to achieving a stable bone-implant construct. Though tritanium cones have been used to manage bone defects in rTKA, their biomechanical performance with varying defects remains unknown.

Methods: Uncontained tibial bone defects at four anatomic locations, with varying depths and widths (Type T2A and T2B) were investigated computationally in a composite tibia which was subjected to four loading scenarios. The ability of the tritanium cone to replace the tibial bone defect was examined using the outcome measures of bone strain distribution and interface micromotions.

Results: It was found that anterior and lateral defects do not significantly alter the strain distribution compared with intact bone. For medial defects, strain distribution is sensitive to defect width; while strain distributions for posterior defects are associated with defect width and depth. In general, micromotions at the bone-implant interface are small and are primarily influenced by defect depth.

Conclusions: Our models show that the cone is an acceptable choice for bone defect management in rTKA. Since all observed micromotions were small, successful osteointegration would be expected in all types of uncontained defects considered in this study. Tritanium cones safely accommodate uncontained tibial defects up to 10 mm deep and extending up to 9 mm from the centre of the cone. Medial and posteriorly based defects managed with symmetric cones display the greatest bone strains and asymmetric cones may be useful in this context.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2020.02.019DOI Listing

Publication Analysis

Top Keywords

tritanium cones
12
bone defects
12
strain distribution
12
defects
10
bone
9
uncontained tibial
8
tibial bone
8
bone defect
8
defect width
8
cones
5

Similar Publications

A finite element analysis of tibial tritanium cones without stems in varying bone defects.

Knee

June 2020

School of Engineering, Institute for Bioengineering, The University of Edinburgh, Alrick Building, The King's Buildings, Edinburgh EH9 3BF, UK. Electronic address:

Background: In the UK around 10% of hip and knee arthroplasties are revision operations. At revision total knee arthroplasty (rTKA), bone loss management is critical to achieving a stable bone-implant construct. Though tritanium cones have been used to manage bone defects in rTKA, their biomechanical performance with varying defects remains unknown.

View Article and Find Full Text PDF

Aims: Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!