Primary high-risk human papillomavirus (hrHPV) DNA testing has been introduced in several countries worldwide, including The Netherlands. The objective of this study was to compare three automated workflow procedures for hrHPV testing of which the hrHPV detection assays meet the international guidelines for HPV testing. To mimic a realistic screening situation, we aimed to process 15 000 residual PreservCyt cervical samples in a period of 3 months. During a 3 months period, four technicians were involved in processing 5000 specimens per month on three automated platforms, (1) Qiagen Digene® HC2 HPV DNA test (HC2, signal amplification); (2) Roche Cobas® HPV test (DNA amplification), and (3) Hologic Aptima® HPV test (RNA amplification). We measured and scored general aspects (time-to-results, hands-on-time (HOT)), maintenance, pre-run, run and post-run aspects, inventory (orders, storage), and number of errors on a scale from 1 to 10. As determined for one complete workflow each, maximum processing capacity and HOT were 296 samples and 2 h:55 m, 282 samples and 3 h:20 m, and 264 samples and 4 h:15 m for Aptima, Cobas, and HC2, respectively. The mean throughput time per run was 5 h:51 m for Cobas in which 94 samples could be processed. For Aptima, the mean throughput time per run was 6 h:30 m for 60 samples. Mean throughput time for HC2 is longer since results were provided on day 2. In this study, the fully automated Aptima workflow scores best with a 7.2, followed by Cobas with a score of 7.1 and HC2 with a score of 5.8. Although all HPV tests used in this comparison meet the international test guidelines, the performance (workflow) characteristics of the assays vary widely. A specific choice of a laboratory for high-throughput testing can be different based on the laboratory's demands, but also hands-on-time, time-to-results/ # samples, maintenance, pre-run, run and post-run parameters, consumables, technical support, and number of errors are important operational factors for the selection of a fully automated workflow for hrHPV testing.

Download full-text PDF

Source
http://dx.doi.org/10.1111/apm.13064DOI Listing

Publication Analysis

Top Keywords

three automated
12
throughput time
12
hpv testing
8
automated workflow
8
hrhpv testing
8
meet international
8
hpv test
8
maintenance pre-run
8
pre-run post-run
8
number errors
8

Similar Publications

Objective: This retrospective study aimed to evaluate morphometric changes in mandibular condyles of patients with skeletal Class III malocclusion following two-jaw orthognathic surgery planned using virtual surgical planning (VSP) and analysed with automated three-dimensional (3D) image analysis based on deep-learning techniques.

Materials And Methods: Pre-operative (T1) and 12-18 months post-operative (T2) Cone-Beam Computed Tomography (CBCT) scans of 17 patients (mean age: 24.8 ± 3.

View Article and Find Full Text PDF

To assess the choroidal vessels in healthy eyes using a novel three-dimensional (3D) deep learning approach. In this cross-sectional retrospective study, swept-source OCT 6 × 6 mm scans on Plex Elite 9000 device were obtained. Automated segmentation of the choroidal layer was achieved using a deep-learning ResUNet model along with a volumetric smoothing approach.

View Article and Find Full Text PDF

Background: Cardiovascular diseases such as coronary artery disease (CAD) have a high prevalence of psychiatric comorbidities, that may impact clinically relevant outcomes (e.g., cognitive impairment and executive dysfunction).

View Article and Find Full Text PDF

Basic Science and Pathogenesis.

Alzheimers Dement

December 2024

PCM Consulting, Pathways Connectivity Maps Inc., Mountain View, CA, USA.

Background: High-throughput assays have attracted significant attention in Alzheimer's Disease (AD) research, especially for enabling rapid diagnostics screening for factors at the molecular level contributing to the disease recurrence. With advances in laboratory automation, there is a growing need for quality pre-clinical data. Assays such as Microarrays, Proteomics, or AI are all dependent on high-quality input data that serve as a starting point.

View Article and Find Full Text PDF

Clinical Manifestations.

Alzheimers Dement

December 2024

Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.

Background: This study responds to the urgent need for automated and reliable methods to detect cognitive impairments on a large scale. It leverages natural language processing (NLP) techniques to predict dementia and mild cognitive impairment (MCI) using clinical notes from electronic health records (EHR).

Method: Our study used an EHR dataset from Massachusetts General Brigham, which included clinical notes from a 2-year period (2017-2018) covering 12 types of patient encounters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!