Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Few risk factors for fracture in magnetically controlled growing rods (MCGR) have been identified. We hypothesize an increased rate of rod fracture in small diameter rods compared to large diameter rods in patients with early-onset scoliosis (EOS). The purpose of this study was to determine the association between the diameter of MCGR constructs and the rate of rod fracture.
Methods: Patients with EOS who underwent MCGR implantation-primary or conversion-from 2013 to 2018 were identified from two registries including 40 centers. Rod diameter sizes greater than 5.0 mm or less than or equal to 5.0 mm were defined as "Large" and "Small" rods, respectively. Only dual-rod constructs were included. The primary outcome measure collected was rod fracture at any point in treatment up to the most recent follow-up. Cox regression was utilized for unequal follow-up to compare rate of breakage at the last follow-up between cohorts.
Results: 527 patients with 1,054 rods were included. 552 (52.4%) rods had a diameter of less than or equal to 5.0 mm and 461 (43.7%) rods had a diameter of greater than 5.0 mm. 41 (3.9%) rods were missing a recorded rod diameter and were not included in the analysis to determine the association between the rate of fracture and rod diameter. 20 (1.9%) total rod fractures occurred: 9 (1.6%) rods with diameters of ≤ 5.0 mm, 10 (2.2%) rods with diameters of > 5.0 mm, and 1 uncategorized rod (p = 0.529). No difference in the rate of rod fracture or survival distribution was found between rod diameters of > 5.0 mm and ≤ 5.0 mm even after stratification by ambulatory status, major coronal curve, weight, or location of anchors.
Discussion: Rod fracture appears to be a rare event in dual MCGR constructs and rod diameter does not seem to be associated with the incidence or rate of rod fracture. Surgeons may consider other criteria for selecting rod diameter in their patients such as patient size, amount of surgical correction, single vs. dual constructs, and risk of hardware prominence.