Calculation of peripheral capillary oxygen saturation [Formula: see text] levels in humans is often made with a pulse oximeter, using photoplethysmography (PPG) waveforms. However, measurements of PPG waveforms are susceptible to motion noise due to subject and sensor movements. In this study, we compare two [Formula: see text]-level calculation techniques, and measure the effect of pre-filtering by a heart-rate tuned comb peak filter on their performance. These techniques are: (1) "Red over Infrared," calculating the ratios of AC and DC components of the red and infrared PPG signals,[Formula: see text], followed by the use of a calibration curve to determine the [Formula: see text] level Webster (in: Design of pulse oximeters, CRC Press, Boca Raton, 1997); and (2) a motion-resistant algorithm which uses the Discrete Saturation Transform (DST) (Goldman in J Clin Monit Comput 16:475-83, 2000). The DST algorithm isolates individual "saturation components" in the optical pathway, which allows separation of components corresponding to the [Formula: see text] level from components corresponding to noise and interference, including motion artifacts. The comparison we provide here (employing the two techniques with and without pre-filtering) addresses two aspects: (1) accuracy of the [Formula: see text] calculations; and (2) computational complexity. We used both synthetic data and experimental data collected from human subjects. The human subjects were tested at rest and while exercising; while exercising, their measurements were subject to the impacts of motion. Our main conclusion is that if an uninterrupted high-quality heart rate measurement is available, then the "Red over Infrared" approach preceded by a heart-rate tuned comb filter provides the preferred trade-off between [Formula: see text]-level accuracy and computational complexity. A modest improvement in [Formula: see text] estimate accuracy at very low SNR environments may be achieved by switching to the pre-filtered DST-based algorithm (up to 6% improvement in [Formula: see text] level accuracy at -10 dB over unfiltered DST algorithm and the filtered "Red over Infrared" approach). However, this improvement comes at a significant computational cost.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8286955PMC
http://dx.doi.org/10.1007/s10877-020-00539-2DOI Listing

Publication Analysis

Top Keywords

[formula text]
24
heart-rate tuned
12
tuned comb
12
"red infrared"
12
text] level
12
[formula
8
ppg waveforms
8
[formula text]-level
8
dst algorithm
8
components corresponding
8

Similar Publications

Modeling, evaluation and metrics performance of the SyncLMKD in distributed kinematics variations.

Sci Rep

January 2025

Graduate Program in Electrical and Computer Engineering, Universidade Tecnológica Federal do Paraná (UTFPR), Curitiba, 80230-901, Brazil.

Modeling the Digital Twin (DT) is an important resource for accurately representing the physical entity, enabling it to deliver functional services, meet application requirements, and address the disturbances between the physical and digital realms. This article introduces the Log Mean Kinematics Difference Synchronization (SyncLMKD) to measure the kinematic variations distributed among Digital Twin elements to ensure symmetric values relative to a reference. The proposed method employs abductive reasoning and draws inspiration from the Log Mean Temperature Difference (LMTD).

View Article and Find Full Text PDF

Study on the foam production characteristics of air self-suction foam generator by jet.

Sci Rep

January 2025

Key Laboratory of Gas and Fire Control for Mines, Ministry of Education, Xuzhou, 221116, China.

Confined space fires could easily cause serious casualties and property damage, and foam is an effective means of preventing confined space fires. The existing foam generator does not have both momentum and foam expansion rate (FER) and is poorly suited to confined spaces. In order to develop a foam generator suitable for confined space fire protection, an in-depth analysis of the physical foaming characteristics of self-suction foam is required, and the structure of the foam generator is optimized accordingly.

View Article and Find Full Text PDF

Aneurysm rupture is a life-threatening event, yet its underlying mechanisms remain largely unclear. This study investigated the fracture properties of the thoracic aneurysmatic aorta (TAA) using the symmetry-constraint Compact Tension (symconCT) test and compared results to native and enzymatic-treated porcine aortas' tests. With age, the aortic stiffness increased, and tissues ruptured at lower fracture energy [Formula: see text].

View Article and Find Full Text PDF

Gastrointestinal absorption and its regulation of hawthorn leaves flavonoids.

Sci Rep

January 2025

School of Pharmacy, Fudan University, 826 Zhangheng Road, Shanghai, 201203, P.R. China.

Hawthorn leave flavonoids (HLF) are widely used as an herb or dietary supplements for cardio-cerebrovascular diseases. However, its gastrointestinal absorption behavior and mechanism have not been disclosed. In this study, gastrointestinal absorption and its regulation of 4''-O-glucosylvitexin (GLV), 2''-O-rhamnosylvitexin (RHV), vitexin (VIT), rutin (RUT) and hyperoside (HP) in HLF were investigated using in vitro, in situ and in vivo models.

View Article and Find Full Text PDF

The proteome is a terminal electron acceptor.

Proc Natl Acad Sci U S A

January 2025

Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125.

Microbial metabolism is impressively flexible, enabling growth even when available nutrients differ greatly from biomass in redox state. , for example, rearranges its physiology to grow on reduced and oxidized carbon sources through several forms of fermentation and respiration. To understand the limits on and evolutionary consequences of this metabolic flexibility, we developed a coarse-grained mathematical framework coupling redox chemistry with principles of cellular resource allocation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!