A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Usefulness of a blood glucose and ketone monitoring device as a screening tool for lethal diabetic ketoacidosis. | LitMetric

Diabetic ketoacidosis (DKA) is a frequent and life-threatening complication, whose diagnosis remains challenging in forensic practice. We aimed at assessing the performance of a commercially available blood glucose and ketone monitoring device (BGMD) in measuring glucose and ketone levels in post-mortem vitreous (VH) and blood samples, in order to determine if such a device can be used for screening lethal cases of DKA at autopsy. VH and blood samples were collected in cases of unexplained causes of death at autopsy. Glucose and β-hydroxybutyrate (BHB) were measured in VH and BHB in blood using the BGMD. The values were compared to those obtained with validated enzymatic methods. Values ≥ 10 mmol/L were considered to be elevated for glucose, and BHB values ≥ 2.5 mmol/L were considered to indicate ketoacidosis. There was a strong and significant correlation between VH glucose and blood BHB concentrations measured with the BGMD and the validated method (r = 0.78 and r = 0.80, p < 0.0001, respectively), whereas no correlation was found for VH BHB values (r = 0.19, p = 0.19). The sensitivity and specificity of the BGMD were both excellent (1.0) to detect elevated VH glucose levels with a threshold of 14.4 mmol/L, and to detect elevated blood BHB levels with a threshold of 2.85 mmol/L. In contrast, the specificity of the BGMD to detect high BHB levels in VH was poor (0.50) with an optimal threshold of 2.5 mmol/L. We showed that a commercially available BGMD is suitable for identifying cases of lethal DKA and other metabolic disorders at autopsy, through the investigation of vitreous glucose and blood BHB. We therefore recommend the systematic use of a BGMD for screening these conditions in cases of unexplained deaths.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00414-020-02343-8DOI Listing

Publication Analysis

Top Keywords

glucose ketone
12
blood glucose
8
ketone monitoring
8
monitoring device
8
device screening
8
diabetic ketoacidosis
8
blood samples
8
blood
6
glucose
5
screening tool
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!