Study Design: Systematic review.
Objective: To review the current clinical use of 3-dimensional printed (3DP) patient-specific implants in the spine.
Summary Of Background Data: Additive manufacturing is a transformative manufacturing method now being applied to spinal implants. Recent innovations in technology have allowed the production of medical-grade implants with unprecedented structure and customization, and the complex anatomy of the spine is ideally suited for patient-specific devices. Improvement in implant design through the process of 3DP may lead to improved osseointegration, lower subsidence rates, and faster operative times.
Methods: A comprehensive search of the literature was conducted using Ovid MEDLINE, EMBASE, Scopus, and other sources that resulted in 1842 unique articles. All manuscripts describing the use of 3DP spinal implants in humans were included. Two independent reviewers (N.W. and N.E.S.) assessed eligibility for inclusion. The following outcomes were collected: pain score, Japanese Orthopedic Association (JOA) score, subsidence, fusion, Cobb angle, vertebral height, and complications. No conflicts of interest existed. No funding was received for this work.
Results: A total of 17 studies met inclusion criteria with a total of 35 patients. Only case series and case reports were identified. Follow-up times ranged from 3 to 36 months. Implant types included vertebral body replacement cages, interbody cages, sacral reconstruction prostheses, iliolumbar rods, and a posterior cervical plate. All studies reported improvement in both clinical and radiographic outcomes. 11 of 35 cases showed subsidence >3 mm, but only 1 case required a revision procedure. No migration, loosening, or pseudarthrosis occurred in any patient on the basis of computed tomography or flexion-extension radiographs.
Conclusions: Results of the systematic review indicate that 3DP technology is a viable means to fabricate patient-matched spinal implants. The effects on clinical and radiographic outcome measures are still in question, but these devices may produce favorable subsidence and pseudoarthrosis rates. Currently, the technology is ideally suited for complex tumor pathology and atypical bone defects. Future randomized controlled trials and cost analyses are still needed.
Level Of Evidence: IV-systematic review.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BSD.0000000000001026 | DOI Listing |
MethodsX
December 2024
Department of Mechanical Engineering, Mepco Schlenk Engineering College, Sivakasi 626005, Tamil Nadu, India.
This paper provides a thorough analysis of recent advancements and emerging trends in the integration of metal additive manufacturing (AM) within orthopedic implant development. With an emphasis on the use of various metals and alloys, including titanium, cobalt-chromium, and nickel-titanium, the review looks at their characteristics and how they relate to the creation of various orthopedic implants, such as spinal implants, hip and knee replacements, and cranial-facial reconstructions. The study highlights how metal additive manufacturing (AM) can revolutionize the field by enabling customized implant designs that take patient anatomical variances into account.
View Article and Find Full Text PDFCureus
December 2024
Department of Orthopaedics, Gandhi Medical College, Bhopal, Bhopal, IND.
Introduction Thoracolumbar fractures, particularly burst fractures, represent a significant health concern due to their prevalence and functional impact. This study evaluates the efficacy of short-segment posterior fixation with intermediate screw instrumentation in treating unstable thoracolumbar fractures. Methods A prospective study was conducted from July 2022 to December 2023, including 26 patients with traumatic thoracolumbar fractures.
View Article and Find Full Text PDFBackground: The goal of this study was to examine the effects of spinal cord stimulation (SCS) on muscle activity during walking after lower-limb amputation. Amputation results in a loss of sensory feedback and alterations in gait biomechanics, including co-contractions of antagonist muscles about the knee and ankle, and reduced pelvic obliquity range-of-motion and pelvic drop. SCS can restore sensation in the missing limb, but its effects on muscle activation and gait biomechanics have not been studied in people with lower-limb amputation.
View Article and Find Full Text PDFJ Orthop
July 2025
Orthopedic Spine Surgeon, USA.
Background: High-grade Isthmic Spondylolisthesis often requires surgical intervention for spinal realignment and decompression. This study describes a modified Bohlman procedure utilizing robotic-assisted navigation and a Globus SI-LOK interbody device.
Methods: A retrospective review was conducted on three patients who underwent the modified Bohlman procedure for high-grade spondylolisthesis at a single hospital between 2022 and 2023.
JOR Spine
March 2025
Beijing Key Laboratory for Design and Evaluation Technology of Advanced Implantable & Interventional Medical Devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering Beihang University Beijing China.
Background: Growth rods are the gold standard for treating early-onset scoliosis (EOS). However, current treatments with growth rods do not optimize spinal growth in EOS patients, and frequent distraction surgeries significantly increase complications, imposing considerable economic and psychological burdens on patients. An improved growth rod is urgently required to address the need for dynamic growth and external regulation.