A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement of Pressures Generated in Root Canal During Er:YAG Laser-Activated Irrigation. | LitMetric

Measurement of Pressures Generated in Root Canal During Er:YAG Laser-Activated Irrigation.

Photobiomodul Photomed Laser Surg

Medical Faculty, Department of Endodontics and Restorative Dentistry, University of Ljubljana, Ljubljana, Slovenia.

Published: October 2020

To measure distribution of pressures along the depth of the root canal during erbium-doped yttrium aluminum garnet (Er:YAG) laser-activated irrigation (LAI) with different modalities and fiber tip (FT) geometries. A new LAI modality based on the delivery of synchronized pairs of Er:YAG laser pulses to generate enhanced irrigant streaming and shock wave emission was recently introduced. However, the influence of FT geometry on efficacy and comparison with single pulse modality is not yet presented. Pressures within a simulated root canal were simultaneously measured at 5 depths during LAI. Seven FT geometries (conical and cylindrical) and two modalities [Super Short Pulse (SSP) and dual pulse AutoSWEEPS] were compared. Under the same conditions, average pressures using SSP at 20 mJ of laser energy ranged from 111 Pa for a conical 600 μm FT to 225 Pa for a flat 400 μm FT. The measured pressures for the SSP and the AutoSWEEPS at 20 mJ laser energy were 223 and 308 Pa at the most coronal level and 119 and 126 Pa at the apical constriction, respectively. Measured pressures and irrigant penetration depths at different root canal levels were found to be linearly correlated ( = 0.82;  < 0.01). The generated pressures get progressively reduced from the coronal toward the apical third of the root canal. A strong dependence on the FT design and laser modality was observed. Within the limitations of the study, the AutoSWEEPS modality is more effective than standard SSP in generating pressures within the root canal, without increasing the risk of extrusion.

Download full-text PDF

Source
http://dx.doi.org/10.1089/photob.2019.4776DOI Listing

Publication Analysis

Top Keywords

root canal
16
eryag laser-activated
8
laser-activated irrigation
8
pressures ssp
8
20 mj laser
8
laser energy
8
measured pressures
8
pressures
5
measurement pressures
4
pressures generated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!